- 1. SET TIMEOUT to ON. Key in a value from 1-30 minutes. If SET TIMEOUT is set to OFF, you will not be able to set the SCREEN BLANKER.
- 2. Set the SCREEN BLANKER password. Key in a password that is 8 characters long (allowed characters are A-Z and 0-9). If you have not changed the default password, you can press [Enter] to cancel SCREEN LOCK.
- 3. Set the SCREEN LOCK to ON. Key in Y. If the SCREEN LOCK function is set to ON, a password is needed to the leave the SCREEN BLANKER mode and return to the OSD.
- Keyboard Emulation
- The Firmware Upgrade Utility
- Before you Begin
- 2. Choose the Firmware Upgrade Package you want to install (usually the most recent), and download it to your computer.
- 3. Use the Firmware Upgrade Cable provided to connect a COM port on your computer to the Firmware Upgrade Port of your switch.
- 4. Shut down the computers on your CS1732B / CS1734B installation.
- 5. Invoke Firmware Upgrade Mode (see FIRMWARE UPGRADE, page 33).
- Starting the Upgrade
- Upgrade Succeeded
- Upgrade Failed
- Before you Begin
- Appendix
CS1732B / CS1734B User Manual
32
(Continued from previous page.)
(Continues on next page.)
Setting Function
BUTTON
SETTINGS
Sets the Front Panel Pushbutton Switching Operation Setting:
MODE 1 (Default Setting):
1. Press a pushbutton once to bring the KVM, Audio and USB focus
simultaneously to the computer attached to its corresponding port (in 2 secs).
2. Press a pushbutton twice to bring the Audio focus to the computer attached
to its corresponding port (in 2 secs).
3. Press a pushbutton for longer than 2 seconds to bring only the KVM focus to
the computer attached to its corresponding port.
4. Press pushbuttons 1 and 2 simultaneously for 2 seconds to start Auto Scan
Mode.
5. Press pushbuttons 3 and 4 simultaneously for 2 seconds to perform a
keyboard and mouse reset. (CS1734B only).
MODE 2 (Alternative Setting)
1. Press a pushbutton once to bring only the KVM focus to the computer
attached to its corresponding port (in 2 secs).
2. Press a pushbutton twice to bring the audio focus to the computer attached to
its corresponding port (in 2 secs).
3. Press a pushbutton for longer than 2 seconds to bring the KVM, Audio and
USB focus simultaneously to the computer attached to its corresponding port.
4. Press pushbuttons 1 and 2 simultaneously for 2 seconds to start Auto Scan
Mode.
5. Press pushbuttons 3 and 4 simultaneously for 2 seconds to perform a
keyboard and mouse reset. (CS1734B only)
PORT
DISPLAY
DURATION
Determines how long a Port displays on the monitor after a port
change. The choices are User Defined (from 0–255 secs), the default
value is 0, which shows as OFF. If you specify 5 and press [Enter], the
Port Display Duration will be saved as 5 SEC.
Note: A value of 0 (zero) will disable the Port Display Duration
function. This shows as OFF.
SCAN
DURATION
Determines how long the focus dwells on each port as it cycles through
the selected ports in Auto Scan Mode. Key in a value from 1–255
seconds (the default is 5 secs) and press [Enter] to save the setting.
SCREEN
BLANKER
SET TIMEOUT: OFF and SCREEN LOCK: OFF is the default setting.
Settings steps:
1. SET TIMEOUT to ON. Key in a value from 1–30 minutes. If SET TIMEOUT is
set to OFF, you will not be able to set the SCREEN BLANKER.
2. Set the SCREEN BLANKER password. Key in a password that is 8
characters long (allowed characters are A–Z and 0–9). If you have not
changed the default password, you can press [Enter] to cancel SCREEN
LOCK.
3. Set the SCREEN LOCK to ON. Key in Y. If the SCREEN LOCK function is set
to ON, a password is needed to the leave the SCREEN BLANKER mode and
return to the OSD.