User Manual
Table Of Contents
- CS1732B / CS1734B User Manual
- Introduction
- Hardware Setup
- Basic Operation
- Keyboard Port Operation
- OSD Operation
- OSD Overview
- OSD Navigation
- OSD Main Screen Headings
- OSD Functions
- F3: SCAN
- F4: SET
- 1. SET TIMEOUT to ON. Key in a value from 1-30 minutes. If SET TIMEOUT is set to OFF, you will not be able to set the SCREEN BLANKER.
- 2. Set the SCREEN BLANKER password. Key in a password that is 8 characters long (allowed characters are A-Z and 0-9). If you have not changed the default password, you can press [Enter] to cancel SCREEN LOCK.
- 3. Set the SCREEN LOCK to ON. Key in Y. If the SCREEN LOCK function is set to ON, a password is needed to the leave the SCREEN BLANKER mode and return to the OSD.
- Keyboard Emulation
- The Firmware Upgrade Utility
- Before you Begin
- 2. Choose the Firmware Upgrade Package you want to install (usually the most recent), and download it to your computer.
- 3. Use the Firmware Upgrade Cable provided to connect a COM port on your computer to the Firmware Upgrade Port of your switch.
- 4. Shut down the computers on your CS1732B / CS1734B installation.
- 5. Invoke Firmware Upgrade Mode (see FIRMWARE UPGRADE, page 33).
- Starting the Upgrade
- Upgrade Succeeded
- Upgrade Failed
- Before you Begin
- Appendix
7. The Firmware Upgrade Utility
39
4. After you have made your device selection(s), Click Next to perform the
upgrade.
If you enabled Check Firmware Version, the Utility compares the device’s
firmware level with that of the upgrade files. If it finds that the device’s
version is higher than the upgrade version, it brings up a dialog box
informing you of the situation and gives you the option to Continue or
Cancel.
If you didn’t enable Check Firmware Version, the Utility installs the
upgrade files without checking whether they are a higher level, or not.
As the Upgrade proceeds status messages appear in the Status Messages
panel, and the progress toward completion is shown on the Progress bar.
Upgrade Succeeded
After the upgrade has completed, a screen appears to inform you that the
procedure was successful:
Click Finish to close the Firmware Upgrade Utility.
After a successful completion, the switches exit Firmware Upgrade Mode, and
reset themselves.
The firmware [Ver 1.0.] is not newer than the current firmware
[Ver 1.0.090] in device CS1732B/CS1734B [MAIN]: 000
Continue the upgrade? [Yes/No]
CS1732B/1734B [MAIN]..
CS1732B/1734B [MAIN]
CS1732B/1734B [MAIN]
CS1732B/1734B [MAIN]