User Manual


STEAM SOUNDS CHART
Function Idle/Moving
Double click F0 Master Volume Control (4 Steps, same as F12)
F1 Bell on/off
F2 Whistle
F3 Air release
F4 Coupling
F5 Brake squeal (repeat press will increase length)
F6 Conductor
F7 Fire box door open and close
F8 Whistle type select
F9 Steam associated sound
F10 Water
F11 Blower hiss
F12 Master Volume Control (4 steps, off, min, mid, max)
F13 Coal auger
F14 Air hose firing
F15 Air Release
F16 Shoveling
F17 Safety Air Pump
F18 Sand
F19* Bell type select
F20* Bell Ring Rate
F21* Bell Volume
F22 Whistle Volume Control
F23 Chuff Volume Control
F24 Chuff Type
F25 Air Brake Release
F26 Coupler
F27 Fire box door close
F28 Firebox door open
Note: There are only a few DCC Systems on the market that can
access functions higher than F12
*Note: F1 [Bell] does not have to be activated when using F190, F20
and F21. The Bell will come on automatically. Use F1 to turn off
after using these functions for Bell adjustment.
CV CHART
CV Register Description Range Default
CV1 R1 Short address 1-127 3
CV2 R2 Start voltage 0-32 0
CV3 R3 Acceleration 0-32 8
CV4 R4 Deceleration 0-32 8
CV5 --- Top voltage 0-32 24
--- R6 Page number --- ---
CV29 R5 Basic configuration --- 2
CV7 R7 Manufacturer version number --- 32
CV8 R8 Manufacturer ID --- 143
CV17 --- Long address upper byte 192-231 192
CV18 --- Long address lower byte 0-255 3
CV19 --- Advanced consist address 0-127 0
CV21 --- When CV21=0, all accessory
functions will follow its own
address. When CV21=1, all
functions will follow the con-
sist address
0-1 0
CV49 Master Volume Control (0=o
ff,1=low,2=mid,3=max)
0-3 2
CV50 --- Whistle type 0-14 0
CV51 --- Whistle volume 0-3 3
CV52 --- Bell type 0-3 0
CV53 --- Bell volume 0-3 3
CV54 --- Bell ring rate 0-50 10
CV55 --- Chuff type 0-3 0
CV56 --- Chuff volume 0-3 3
CV57 --- Brake squeal volume 0-3 1
CV58 --- Air release volume 0-3 3
CV59 --- Blower hiss volume 0-3 3
CV60 --- Fire box door volume 0-3 3
CV61 --- Injector volume 0-3 3
CV62 --- Coupling volume 0-3 3
CV63 --- Air pump volume 0-3 0
CV105 --- User identification number 0-255 0
CV106 --- User identification number 0-255 0
CV112 --- Conductor volume 0-3 3
CV114 Air pump type 0-3 1
CV118 --- Shoveling volume 0-3 3
CV119 --- Coupling fire volume 0-3 3
CV Register Description Range Default
CV120 --- Chuff rate 0-30 12
CV121 --- Chuff start point adjustment 0-7 3
CV122 Double chuff enable 0-1 1
(enable)
CV123 Load Control on/off (1=on) 0-1 0
(disable)
CV124 Speed curve select (0=linear,
1=slow increase at slow
speed, 2=fast increase at slow
speed
0-2 0
CV125 --- Factory default setting: Pro-
gram it to 1 will restore all the
CV to default setting
--- 0