SERIES IMP IMP/P SAM HOT RUNNER CONTROLLERS Instruction Manual
Two-Year Limited Warranty THIS EQUIPMENT IS WARRANTED TO BE FREE FROM DEFECTS OF MATERIAL AND WORKMANSHIP. IT IS SOLD SUBJECT TO OUR MUTUAL AGREEMENT THAT THE LIABILITY OF THE MANUFACTURER IS TO REPLACE OR REPAIR THIS EQUIPMENT AT ITS FACTORY, PROVIDED THAT IT IS RETURNED WITH TRANSPORTATION PREPAID WITHIN TWO (2) YEARS OF ITS PURCHASE.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual Table of Contents Section 1 1.1 1.2 1.3 Section 2 2.1 2.2 2.3 2.4 IMP I IMP/P Series General Description...................................... 3 Installation (IMP Series Only)....................... 4 Operation...................................................... 4 Model SAM Communications Module Installation.................................................... General Specifications.................................. Basic Operation............
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual IMP SERIES OPERATING INSTRUCTIONS ALARM/MODE DISPLAY DISPLAY ALARM SYMBOLS DOT INDICATORS POWER BEING DELIVERED TO LOAD OVER TEMPERATURE THERMOCOUPLE OPEN MANUAL MODE ON (DISPLAY INDICATES PERCENTAGE OF POWER) NO HEAT REMOTE AND STANDBY OPERATION % UNDER TEMPERATURE THERMOCOUPLE REVERSED DIGITAL SETPOINT SWITCH ACCURATELY SETS A SETPOINT TEMPERATURE TEMPERATURE AND PERCENTAGE POWER DISPLAY STANDBY (WARM) REGION PERCENTAGE POWER ADJUST
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual IMP/P SERIES PORTABLE SINGLE ZONE HORIZONTAL CONTROLLER ALARM/DISPLAY DISPLAY ALARM SYMBOLS OVER TEMPERATURE UNDER TEMPERATURE DIGITAL SETPOINT SWITCH ACCURATELY SETS A SETPOINT TEMPERATURE THERMOCOUPLE OPEN NO HEAT THERMOCOUPLE REVERSED STANDBY (WARM) REGION TEMPERATURE AND PERCENTAGE POWER DISPLAY POWER SWITCH ON 0 OFF MODE SELECT TOGGLE SWITCH DISPLAY MODE SYMBOLS DOT INDICATORS OPEN LOOP (MANUAL MODE) POWER BEING DELIVERED TO LOAD C
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual SECTION 1 OPERATING INSTRUCTIONS IMP Series 15 and 30 Amp Temperature Controllers IMP/P Series 10 and 15 Amp Temperature Controllers 1.1 General Description The IMP and IMP/P Series are microprocessor-based PID controllers specifically designed to perform most operator functions automatically. The IMP Series are plug-in units, while the IMP/P Series are portable, stand-alone instruments.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual The IMP controller also sends alarm status conditions to the SAM auxiliary module for annunciation and remote control functions. 1.2 Installation (IMP Series Only) All IMP Series controllers are ready to use as shipped from the factory. Prior to installation into a mainframe, make sure the voltage, Hz, and degree options are as ordered and correspond to the Product ID label.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual is 30 ºF (17 °C) or more above setpoint, the over temperature alarm display (upper segment of the leftmost digit) will flash. During alarm conditions, temperature display will also flash. If the temperature is within alarm limits, the display will stop flashing, and the leftmost digit will display closed-loop mode (“ ”). 5. Power to load indicator (the decimal point of the leftmost digit) will be on if any power is being applied to the load. 6.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual Manual Open-Loop Operation 1. Position the mode select switch to open-loop (“ ”). 2. Turn the AC power on. 3. After reset delay, the controller will display the percentage of output power as adjusted by the power control knob. The percentage power indicator will be on. Thus 0.00 corresponds to 0% (no power) and 1.00 corresponds to 100% (full power). The leftmost digit will display open-loop mode (“ ”). 75% power is shown as 0.75.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual Standby Heat (SAM module only) Standby heat is a low heat level used to keep heaters and associated equipment warm. Its purpose is to prevent moisture build-up in heaters and equipment during idle periods and to provide fast startup when returning to normal operations. When using a SAM, activate the standby switch. The SAM will send a standby command to all controllers.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual switched to manual mode. The output power will be a function of the manual control knob setting. Since the controller is now operating in open-loop mode, extreme care must be taken when adjusting to prevent excess output power that would overheat the load. 4. No heat: The IMP series controller has included in its microprocessor a program that detects that the temperature is not rising as it should in response to full power output.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual User’s Selected Jumper Option 1. For degree Celsius operation, install jumper on PC board marked J1 (marked C on newer models) 2. For 50 Hz operation, install jumper on PC board marked J2 (automatic on units built after 1999) 3. For 120 Vac input operation, install the 2 jumpers on the PC board as shown. 4. For 240 Vac input operation, install the 1 jumper on the PC board as shown.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual SafeChange. SafeChange should be enabled on the controller before installing it in the mainframe to reduce the possibility of damage to the controller. Use of the SafeChange feature does not eliminate the need for careful installation and removal of controllers. Always turn off power to the controller and the mainframe when installing or removing a controller.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual If you don’t see JP6, the controller in hand may pre-date the SafeChange feature. In addition to JP6 in the location shown above, controllers that support SafeChange also have one edge connector shorter than the others. If all the edge connectors are the same length, the controller does not support the SafeChange feature. SafeChange Edge Connector 4.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual SECTION 2 OPERATING INSTRUCTIONS Model SAM Communications Module 2.1 Installation CAUTION Never insert or remove the module from a mainframe with the AC power on. Always switch the module or mainframe to OFF. Hazardous potentials exist on components inside both the module and mainframe. Always disconnect the AC power to the mainframe when servicing.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual 2.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual SAM MODULE QUICK REFERENCE GUIDE SPEAKER FAST, HIGH TONE = OVER TEMPERATURE 30°F (17°C) OR MORE ABOVE SETPOINT SLOW, LOW TONE = UNDER TEMPERATURE 30°F (17°C) OR MORE BELOW SETPOINT LOW TEMP ALARM MODE SWITCH LOW TEMP ALARM MODE INHIBIT LOW TEMP ALARM ACTIVE EXTERNAL OUTPUT CONNECTOR PINS 1 & 2 - N.C. RELAY CONTACTS OVER TEMP. LED (red) UNDER TEMP. LED (red) PINS 1 & 3 - N.O.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual 2.3 Basic Operation 1. Select Normal or Standby Mode. 2. Select Low Temperature Alarm Mode. a. Low Temperature Alarm Inhibit : Speaker will be off and output relay inactive in the event of low temperature condition (useful during start-up procedures). b. Low Temperature Alarm Active : 30 °F (17 °C) or more below IMP setpoint temperature will sound alarm and energize output relay contacts. 3. Turn Power On-Off Switch to “ON” position. 4.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual the over temperature LED will flash, and relay closure will occur. b. Under Temp. : Occurs when an IMP-15 thermocouple is 30 ºF (17 ºC) or more below setpoint. The speaker will emit a low-pitched audio tone of about 1 KHz repeating about once per second. At the same time, the under temperature LED will flash, and relay closure will occur. c. Over Temp.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual 5. Remote Standby Option: It is possible to wire the mainframe for remote standby operation as outlined in the following procedure. a. Locate the appropriate communications connector for the zone to be occupied by the SAM. This is on the upper strip of connectors on the rear of the model “MFC” mainframe. b. Carefully wire an isolated set of Normally Open relay contacts, rated at 5 volts and 1/2 amp, to Pins 8 and 12 of the mainframe connector.
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual NOTES 18
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual SERIES IMP/P WIRING & CONNECTION DIAGRAM (FEMALE) (MALE) v v MOLD CABLE END CKPTM1 v CABLE END CKPTF1 v CABLE MPT/C10 (10 FOOT) MPT/C20 (20 FOOT) MAINFRAME CONNECTOR CKPTOC1 MOLD CONNECTOR CKPTIC1 POWER OUT AND THERMOCOUPLE IMP/P 15B NEMA IN, 5 PIN OUT CKPTM1 IMP/P 15A NEMA IN, NEMA OUT POWER IN AC2024F OUTPUT AC INPUT OUTPUT FEMALE PLUG THERMOCOUPLE INPUT 19 POWER OUT THERMOCOUPLE AC1524M M2MJ AC INPUT MALE PLUG MALE P
IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual SERIES IMP/P WIRING & CONNECTION DIAGRAM IMP/P 10B POWER CORD IN, 5 PIN OUT AC INPUT OUTPUT 20
For technical assistance, call toll free 1-800-782-6776 (in the U.S.) or 610-828-2490 (from anywhere in the world), or e-mail techsupport@athenacontrols.com. The Temperature Control Company 900M001U01RevC-0803-1.5M-JA Athena Controls, Inc. 5145 Campus Drive Plymouth Meeting, PA 19462 USA Toll-free: 800.782.6776 Tel: 610.828.2490 Fax: 610.828.7084 techsupport@athenacontrols.com athenacontrols.