Instruction manual

IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual
11
If you don’t see JP6, the
controller in hand may
pre-date the SafeChange
feature. In addition to JP6
in the location shown
above, controllers that
support SafeChange also
have one edge connector
shorter than the others. If all
the edge connectors are the
same length, the controller
does not support the
SafeChange feature.
4. Adding a SafeChange Clip to the Mainframe
You can convert an older mainframe to support
SafeChange. To make the conversion, you must add a clip
to the third position in the lower connector block (on the
backplane) in every slot; see the illustration. The clip is p/n
216D001U01.
To install the clip:
a. Turn off power to the mainframe.
b. Remove the back cover of the mainframe.
c. Position the clip in the third (open) position in the
lower connector block, and press. The clip will
snap into position.
SafeChange Edge Connector