Instruction manual

IMP I IMP/P I SAM Hot Runner Controllers Instruction Manual
17
5. Remote Standby Option: It is possible to wire the mainframe
for remote standby operation as outlined in the following
procedure.
a. Locate the appropriate communications connector for the
zone to be occupied by the SAM. This is on the upper
strip of connectors on the rear of the model “MFC”
mainframe.
b. Carefully wire an isolated set of Normally Open relay
contacts, rated at 5 volts and 1/2 amp, to Pins 8 and 12
of the mainframe connector. Note that this relay is not
included.
c. When the remote relay is energized, SAM will be placed
in the Standby mode of operation.
d. A SAM must be installed for this option to work.