SERIES IMP IMP/P HOT RUNNER CONTROLLERS Instruction Manual
IMP IMP/P Hot Runner Controllers Instruction Manual ©Copyright, Athena Controls, Inc., 2006 Printed in USA Compustep® is a registered trademark of Athena Controls, Inc. Safechange™ is a trademark of Athena Controls, Inc.
IMP IMP/P Hot Runner Controllers Instruction Manual Table of Contents Section 1 1.1 1.2 1.3 IMP I IMP/P Series General Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installation (IMP Series Only) . . . . . . . . . . . . . . . . . . . . . . . . 6 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IMP IMP/P Hot Runner Controllers Instruction Manual IMP SERIES OPERATING INSTRUCTIONS ALARM/MODE DISPLAY DISPLAY ALARM SYMBOLS DOT INDICATORS POWER BEING DELIVERED TO LOAD OVER TEMPERATURE % THERMOCOUPLE OPEN MANUAL MODE ON (DISPLAY INDICATES PERCENTAGE OF POWER) NO HEAT REMOTE AND STANDBY OPERATION UNDER TEMPERATURE THERMOCOUPLE REVERSED DIGITAL SETPOINT SWITCH ACCURATELY SETS A SETPOINT TEMPERATURE TEMPERATURE AND PERCENTAGE POWER DISPLAY STANDBY (WARM) REGION PERCENTAGE POWER ADJUSTMENT KNOB
IMP IMP/P Hot Runner Controllers Instruction Manual IMP/P SERIES PORTABLE SINGLE ZONE HORIZONTAL CONTROLLER ALARM/DISPLAY DISPLAY ALARM SYMBOLS OVER TEMPERATURE UNDER TEMPERATURE DIGITAL SETPOINT SWITCH ACCURATELY SETS A SETPOINT TEMPERATURE THERMOCOUPLE OPEN NO HEAT THERMOCOUPLE REVERSED STANDBY (WARM) REGION TEMPERATURE AND PERCENTAGE POWER DISPLAY POWER SWITCH ON OFF MODE SELECT TOGGLE SWITCH DISPLAY MODE SYMBOLS DOT INDICATORS OPEN LOOP (MANUAL MODE) POWER BEING DELIVERED TO LOAD CLOSED LOOP (
IMP IMP/P Hot Runner Controllers Instruction Manual Section One Operating Instructions To install a plug-in controller into a mainframe, release the locking device on the lower edge of the unit by pulling the plunger gently away from the panel. Align the upper and lower edges of the printed circuit board on the controller with the mainframe card guide slot and slide in until the rear connector is completely engaged. Lock the controller into the frame by depressing the plunger on the locking device.
IMP IMP/P Hot Runner Controllers Instruction Manual 5. 6. Manual Open-Loop Operation temperature display will also flash. If the temperature is within alarm limits, the display will stop flashing, and the leftmost digit will display closed-loop mode (“O”). Power to load indicator (the decimal point of the leftmost digit) will be on if any power is being applied to the load.
IMP IMP/P Hot Runner Controllers Instruction Manual 60-second interval during start-up. It takes 60 seconds to detect “No heat” when power is first turned on in closed-loop mode. seconds, then re-examine the temperature by switching mom entarily to closed-loop mode. Repeat this procedure until the temperature is the same in either automatic or manual control. If CompuStep is active, the test is not performed until after CompuStep is finished (5 minutes).
IMP IMP/P Hot Runner Controllers Instruction Manual 1. User’s Selected Jumper Option 1. Do not enable SafeChange unless the mainframe supports this feature. For degree Celsius operation, install shunt on PC board marked J1 (marked C on newer models) 2. For 120 Vac input operation, install the 2 jumpers on the PC board as shown. 3. For 240 Vac input operation, install the 1 jumper on the PC board as shown.
IMP IMP/P Hot Runner Controllers Instruction Manual 2) If the third position in the connector block does not contain a metal clip, then the mainframe does not support SafeChange. You can add a clip to convert the mainframe. 2. Enabling the SafeChange Feature Controllers are shipped with SafeChange disabled, because the controller will not work if the SafeChange feature is enabled, but the mainframe does not support SafeChange. You can enable SafeChange quickly and easily.
IMP IMP/P Hot Runner Controllers Instruction Manual SERIES IMP/P WIRING & CONNECTION DIAGRAM (FEMALE) (MALE) CABLE END CKPTM1 v v MOLD v CABLE END CKPTF1 v CABLE MPT/C10 (10 FOOT) MPT/C20 (20 FOOT) MAINFRAME CONNECTOR CKPTOC1 MOLD CONNECTOR CKPTIC1 POWER OUT AND THERMOCOUPLE IMP/P 15B NEMA IN, 5 PIN OUT POWER IN CKPTM1 IMP/P 15A NEMA IN, NEMA OUT AC2024F OUTPUT AC1524M OUTPUT AC INPUT FEMALE PLUG POWER OUT AC INPUT THERMOCOUPLE INPUT THERMOCOUPLE M2MJ MALE PLUG MALE PLUG SERIES IM
Two-Year Limited Warranty THIS EQUIPMENT IS WARRANTED TO BE FREE FROM DEFECTS OF MATERIAL AND WORKMANSHIP. IT IS SOLD SUBJECT TO OUR MUTUAL AGREEMENT THAT THE LIABILITY OF THE MANUFACTURER IS TO REPLACE OR REPAIR THIS EQUIPMENT AT ITS FACTORY, PROVIDED THAT IT IS RETURNED WITH TRANSPORTATION PREPAID WITHIN TWO (2) YEARS OF ITS PURCHASE.