Specifications

SAM SERIES
Over/under temperature alarm. Built in standby/night
heat. Audio and relay output. For use with IMP only.
SPECIFICATIONS
Standby
Temperature 200 deg F (93 deg C)
AC Input
Requirements 240 Vac + 10% -20%, 48-63 Hz
(standard) 120 Vac (Available)
Alarm Limits +/- 30° F (17° C) when used
with an IMP
Alarm
Output (Audible) Over Temperature: 2 KHz tone at
2 Hz interval
Under Temperature:1 Hz flashing
interval
Alarm
Output (Visual) Over Temperature: 2 Hz flashing
rate
Under Temperature:1 Hz flashing
rate
Output Connector AMP MIL-style connector (4 Pin) pro-
viding Normally Closed and Normally
Opened relay contacts.
(5 amp maximum)
Communication
Capacity 50 zones maximum
Ordering Information
Market
D = Domestic
X = Export
Special Options
000 = Consult factory
S A M