Calculator User Manual

2-lines display
Scientific Calculator
with advance
statistical functions
Please read before using.
Owner's Manual
AT-30i
Safety Precautions
Be sure to read the following safety precautions before
using this calculator. Keep this manual handy for later
reference.
Batteries
• After removing the batteries from the calculator, put
them in a safe place where there is no danger of them
getting into the hands of small children and accidently
swallowed.
• Keep batteries out of the reach of children. If accidentally
swallowed, consult with a physician immediately.
• Never charge batteries, try to take batteries apart, or
allow batteries to become shorted. Never expose
batteries to direct heat or dispose of them by
incineration.
Misuse of batteries can cause them to leak acid that can
cause damage to nearby items and creates the
possibility of fire and personal injury.
Always make sure that a battery's positive (+) and
negative (–) sides are facing correctly when you load it
into the calculator.
• Remove the batteries if you do not plan to use the
calculator for a long time.
• Use only the type of batteries specified for this calculator
in this manual.
Do not mix old and new batteries. Do not mix alkaline,
standard (carbon-zinc), or rechargeable (nickle cadmium)
batteries.
• Battery Contains Mercury. Do Not Put in Trash. Recycle or
Manage as Hazardous Waste.
Disposing of the Calculator
Never dispose of the calculator by burning it. Doing so
can cause certain components to suddenly burst,
creating the danger of fire and personal injury.
The displays and illustrations (such as key markings)
shown in this Owner's Manual are for illustrative
purposes only, and may differ somewhat from the actual
items they represent.
• The contents of this manual are subject to change
without notice.
Handling Precautions
Be sure to press the "ON/AC" key before using the
calculator for the first time.
Even if the calculator is operating normally, replace the
battery at least once every three years. Dead battery can
leak, causing damage to and malfunction of the
calculator. Never leave the dead battery in the calculator.
• The battery that comes with this unit discharges slightly
during shipment and storage. Because ofthis, it may
require replacement sooner than the normal expected
battery life.
Low battery power can cause memory contents to
become corrupted or lost completely. Always keep
written records of all important data.
• Avoid use and storage in areas subjected to temperature
extremes. Very low temperatures can cause slow display
response,total failure of the display, and shortening of
battery life.Also avoid leaving the calculator in direct
sunlight, neara window, near a heater or anywhere else it
might become exposed to very high temperatures. Heat
can cause discoloration or deformation of the
calculator's case, anddamage to internal circuitry.
Avoid use and storage in areas subjected to large
amounts of humidity and dust. Take care never to leave
the calculator where it might besplashed by water or
exposed to large amounts of humidity or dust. Such
elements can damage internal circuitry.
• Never drop the calculator or otherwise subject it to
strong impact.
• Never twist or bend the calculator. Avoid carrying the
calculator in the pocket of your trousers or other
tight-fitting clothing where it might be subjected to
twisting or bending.
• Never try to take the calculator apart.
Never press the keys of the calculator with a ball-point
pen or other pointed object.
• Use a soft, dry cloth to clean the exterior of the unit. If the
calculator becomes very dirty, wipe it off with acloth
moistened in a weak solution of water and a mildneutral
household detergent. Wring out all excess moisture
before wiping the calculator. Never use thinner, benzine
or other volatile agents to clean the calculator. Doing so
can remove printed markings and damage the case.
Two-lines Display
You can simultaneously check the calculation formula and
its answer. The first line displays the calculation formula.
The second line displays the answer.
Keys Layout
Before Starting Calculations
Operation Modes
When using this calculator, it is necessary to select the
proper mode to meet your requirements. This can be done
by pressing [MODE] to scroll through sub-menus. Then
select the appropriate mode by keying in the number.
Press [MODE] once to read the first page of the main
menu.
Press [MODE] again.
Press [MODE] further.
Press "MODE" once more to leave the menu.
Calculation Modes
"COMP" mode : - general calculations, including function
calculations can be executed.
"SD" mode:- standard deviation calculation can be
executed. "SD" symbol appears in display.
"REG" mode:- regression calculations can be performed.
"REG" symbol appears in display.
Angular Measurement Modes
"DEG" mode:- specify measurement in "degrees". "D"
symbol appears in display window.
"RAD" mode:- specify measurement in "radians". "R"
symbol appears in display window.
"GRA" mode:- specify measurement in "grads". "G"
symbol appears in display window.
Display Modes
"FIX" mode:- specify number of decimal places. "Fix"
symbol appears in display window.
"SCI" mode:- specify number of significant digits. "Sci"
symbol appears in display window.
"NORM" mode:- cancels "Fix" and "Sci" specifications.
Note:-
• Mode indicators appear in the lower part of the display.
The "COMP", "SD", and "REG" modes can be used in
combination with the angle unit modes.
• Be sure to check the current calculation mode (COMP, SD,
REG) and angle unit mode (DEG, RAD, GRA) before
beginning a calculation.
Calculation Priority Sequence
Calculations are performed in the following order of
precedence:-
1. Coordinate transformation: Pol(x, y),Rec(r, )
2. Type A functions :-
These functions are those in which the value is entered
and than the function key is pressed, such as x
2
, x
–1
, x!,
º
'''.
3. Powers and roots, x
y
,
x
4. Fractions, a
b
/c
5. Abbreviated multiplication format in front of π, memory
name or variable name, such as 2π, 5A, πA, etc.
6. Type B functions :-
These functions are those in which the function key is
pressed and then the value is entered such as ,
3
, log,
ln, e
x
, 10
x
, sin, cos, tan, sin
–1
, cos
–1
, tan
–1
, sinh, cosh, tanh,
sinh
–1
, cosh
–1
, tanh
–1
, (–).
7. Abbreviated multiplication format in front of Type B
functions, such as, 23, A log2, etc.
8. Permutation, combination, nPr, nCr
9. ,
10. ,
• When functions with the same priority are used in series,
execution is performed from right to left for :- e
x
ln120
e
x
{ln(120)}. Otherwise, execution is from left to right.
• Operations enclosed in parentheses are performed first.
Stacks
This calculator uses memory areas, called "stacks", to
temporarily store values (numeric stack) and commands
(command stack) according to their precedence during
calculations. The numeric stack has 10 levels and the
command stack has 24 levels. A stack error (stk ERROR)
occurs whenever you try to perform a calculation that is
so complex that the capacity of a stack is exceeded.
Error Loacator
Pressing [3] or [4] after an error occurs display the
calculation with the cursor positioned at the location
where the error occured.
Overflow and Errors
The calculator is locked up while an error message is on
the display. Press [ON/AC] to clear the error, or press [3]
or [4] to display the calculation and correct the problem.
"Ma ERROR" caused by:-
• Calculation result is outside the allowable calculation
range.
Attempt to perform a function calculation using a value
that exceeds the allowable input range.
• Attempt to perform an illegal operation (division by zero,
etc.).
Action
• Check your input values and make sure they are all
within the allowable ranges. Pay special attention to
values in any memory areas you are using.
"Stk ERROR" caused by:-
Capacity of the numeric stack or operator stack is
exceeded.
Action
Simplify the calculation. The numeric stack has 10 levels
and the operator stack has 24 levels.
• Divide your calculation into two or more separate parts.
"Syn ERROR" caused by:-
• Attempt to perform an illegal mathematical operation.
Action
• Press to display the calculation with the cursor located at
the location of the error. Make necessary corrections.
Number of Input/output Digits and Calculation Digits
The memory area used for calculation input can hold 79
"steps". One function comprises one step. Each press of
numeric or , , and keys comprise one step.
Though such operations as [SHIFT] [x!] (x
–1
key) require
two key operations, they actually comprise only one
function, and, therefore, only one step. These steps can be
confirmed using the cursor. With each press of the [3] or
[4] key, the cursor is moved one step.
Whenever you input the 73rd step of any calculation, the
cursor changes from "_" to "" to let you know memory is
running low. If you still need to input more, you should
divide you calculation into two or more parts.
When numeric values or calculation commands are input,
they appear on the display from the left. Calculation
results, however, are displayed from the right.
The allowable input/output range (number of digits) of
this unit is 10 digits for a mantissa and 2 digits for the
exponent. Calculations, however, are performed internally
with a range of 12 digits for a mantissa and 2 digits for an
exponent.
Example: 3 10
5
7 =
3[EXP]5[÷]7[=]
3[EXP]5[÷]7[]42857[=]
Corrections
To make corrections in a formula that is being input, use
the [3] and [4] keys to move to the position of the error
and press the correct keys.
Example: To change an input of 122 to 123 :-
[1] [2] [2]
[3]
[3]
Example: To change an input of cos60 to sin60 :-
[cos] [6] [0]
[3] [3] [3]
[sin]
If after making corrections, input of the formula is
complete, the answer can be obtained by pressing [ = ]. If,
however, more is to be added to the formula, advance the
cursor using the [4] key to the end of the formula for
input.
If an unnecessary character has been included in a
formula, use the [3] and [4] keys to move to the
position of the error and press the "DEL" key. Each press
of "DEL" will delete one command ( one step ).
Example: To correct an input of 369   2 to 369 2 :-
369[][]2
[3][3][DEL]
If a character has been omitted from a formula, use the
[3] and [4] key to move to the position where the
character should have been input, and press [SHIFT]
followed by [INS] key. Each press of [SHIFT] [INS] will
create a space for input of one command.
Example: To correct an input of 2.36
2
to sin 2.36
2
:-
2[•]36[x
2
]
[3][3][3][3][3]
[SHIFT][INS]
[sin]
When [SHIFT] [INS] are pressed, the space that is opened
is displayed as " ". The function or value assigned to the
next key you press will be inserted in the . To exit from
the insertion mode, move the cursors, or press [SHIFT]
[INS] , or press [=].
Even after the [=] key has been pressed to calculate a
result, it is possible to use this procedure for correction.
Press the [3] key to move the cursor to the place where
the correction is to be made.
Arithmetic Operations & Parenthesis Calculations
• Arithmetic operations are performed by pressing the
keys in the same order as noted in the formula.
• For negative values, press [(-)] before entering the value
• For mixed basic arithmetic operations, multiplication and
division are given priority over addition and subtraction
• Assuming that display mode "Norm 1" is selected.
Percentage Calculations
Use the "COMP" mode for percentage calculations.
Specifying the Format of Calculation Results
You can change the precision of calculation results by
specifying the number of decimal places or the number of
significant digits. You can also shift the decimal place of a
displayed value three places to the left or right for
one-touch conversions of metric weights and measures.
Upon power up reset, the display format is defaulted at
"Norm1". Each time when you press "[MODE] [MODE]
[MODE] [3]" you can choose either "Norm 1" or "Norm 2"
by keying in [1] or [2] respectively.
Norm 1 :- all values less than 10
–2
or greater than 10
9
are
automatically expressed as exponents.
Norm 2 :- all values less than 10
–9
or greater than 10
9
are
automatically expressed as exponents.
Note: You cannot specify the display format (Fix, Sci) while
the calculator is in Base-N mode.
Specifying the Number of Decimal Places
The calculator always performs calculations using a
10-digit mantissa and 2-digit exponent, and results are
stored in memory as a 12-digit mantissa and 2-digit
exponent no matter how many decimal places you
specify. Intermediate results and final results are then
automatically rounded off to the number of decimal
places you have specified.
It should be noted that displayed results are rounded
to the specified number of decimal places, but stored
results are normally not rounded.
To specify the number of decimal places ( Fix ), press
"[MODE] [MODE] [MODE] [1]" and then a value
indicating the number of decimal places (0~9).
At this time, you should be able to see "Fix" on the display.
The number of decimal places specified will remain in
effect until "Norm" (to select "Norm" press "[MODE]
[MODE] [MODE] [3]") is specified or significant digits are
specified using "[MODE] [MODE] [MODE] [2]".
[ON/AC] [MODE]
[MODE]
[MODE]
[1]
[4] (to specify 4 decimal places)
Reset to "Norm"
[ON/AC] [MODE]
[MODE]
[MODE]
[3]
[1]
Rounding the Intermediate Result
As the number of decimal places is specified, the
intermediate result will be automatically rounded to the
specified decimal places. However, the stored
intermediate result is not rounded. In order to match the
displayed value and the stored value, [SHIFT] [Rnd] can
be input.
You can compare the final result obtained in the previous
example with the final result of the following example.
Specifying the Number of Significant Digits
This specification is used to automatically round
intermediate results and final results to the number of
digits you have specified.
As with the number of decimal places, displayed results
are rounded to the specified number of digits, but stored
results are normally not rounded.
To specify the number of significant digits (Sci.), select
[SCI] in the sub-menu "FIX/SCI/NORM" and then you are
asked to enter a value indicating the number of significant
digits (0~9) as below.
Note : "0" indicating 10 significant digits.
Meanwhile, the "Sci" indicator will appear on the display.
Shifting the Decimal Place
You can use the key [ENG] to shift the decimal point of
the displayed value three places to the left or right. Each
3-place shift to the left is the same as dividing the value
by 1000, and each shift to the right is the same as
multiplying by 1000. This means that this function is
useful when converting metric weights and measures to
other metric units.
Memory
This calculator contains 9 standard memories. There are
two basic types of memories, i.e., "variable" memories,
which are accessed by using the [STO] and [RCL] keys in
combination with the alphabets A, B, C, D, E, F, M, X and Y.
The "independent" memory, which is accessed by using
the [M+] , [Shift] [M–] and [RCL] and [M] keys. The
independent memory uses the same memory area as
variable M.
Contents of both the variable and independent memories
are protected even when the power is turned OFF.
Variable memories
Up to 9 values can be retained in memory at the same
time, and can be recalled when desired.
Example: Input 123 into memory "A" :-
[ON/AC] 123
[STO] [A]
[ON/AC]
[RCL] [A]
When formulas are input, the result of the formula's
calculation is retained in memory.
Example: Input the result of 123456 into memory "B" :-
[ON/AC] 123 [] 456
[STO] [B]
[ON/AC]
[RCL] [B]
If a variable expression is entered, the expression is first
calculated according to the values stored in the variable
memories used in the expression. The result is then stored
in the variable memory specified for the result.
Example: Input the results of AB into memory "C" :-
[ON/AC] [ALPHA] [A] []
[ALPHA] [B]
[STO] [C]
[ON/AC]
[RCL] [C]
Deleting memories
To delete all contents of variable memories, press [Shift]
followed by [Mcl] [=].
Independent Memory
Addition and subtraction (to and from sum) results can be
stored directly in memory. Results can also be totalized in
memory, making it easy to calculate sums. The icon "M"
will be lighted as long as M is not empty.
Example: Input 123 to independent memory.
[ON/AC] [1] [2] [3]
[M+]
Recall memory data
[ON/AC]
[RCL] [M]
Add 25, subtract 12
25 [M+] 12 [SHIFT] [M–]
Recall memory data
[ON/AC]
[RCL] [M]
To clear memory contents, press [0] [STO] [M].
Addition/subtraction to or from sum in memory cannot
be carried out with [M+], [SHIFT] [M–] keys in "SD" mode
and "REG" mode.
Difference between [STO][M] and [M+], [SHIFT][M–] :-
Both [STO] [M] and [M+], [SHIFT] [M–] can be used to
input results into memory, however when the [STO] [M]
operation is used, previous memory contents are cleared.
When either [M+] or [SHIFT] [M–] is used, value is added
or subtracted to or from present sum in memory.
Example: Input 456 into memory "M" using [STO] [M]
procedure. Memory already contains value of 123.
[ON/AC] [1] [2] [3] [STO] [M]
[ON/AC] [4] [5] [6] [STO] [M]
[ON/AC]
[RCL] [M]
Example: Input 456 into memory "M" using M+. Memory
already contains value of 123.
[ON/AC] [1] [2] [3] [STO] [M]
[ON/AC] [4] [5] [6] [M+]
[ON/AC]
[RCL] [M]
Special Functions
Answer Function
This unit has an answer function that stores the result of
the most recent calculation. Once a numeric value or
numeric expression is entered and [=] is pressed, the
result is stored by this function.
To recall the stored value, press the [Ans] [=] key. When
[Ans] is pressed, "Ans" will appear on the display, and the
value can be used in subsequent calculations.
Example: 123456 = 579
789579 = 210
[ON/AC][1][2][3][][4][5][6][=]
[7][8][9][][Ans]
[=]
Numeric values with 12 digits for a mantissa and 2 digits
for an exponent can be stored in the "Ans" memory. The
"Ans" memory is not erased even if the power of the unit
is turned OFF. Each time [=] , [Shift] [%] , [M+] , [Shift] [M–] ,
and [STO] ( = A ~ F, M, X, Y ) is pressed, the value in the
Ans memory is replaced with the new value produced by
the calculation execution. When execution of a
calculation results in an error, however, the "Ans" memory
retains its current value.
Note:- Contents of "Ans" memory are not altered when
RCL ( = A~F, M, X, Y) is used to recall contents of
variable memory. Also, contents of "Ans" memory are not
altered when variables are input when the variable input
prompt is displayed.
Omitting the multiplication sign ()
When inputting a formula as it is written, from left to right,
it is possible to omit the multiplication sign () in the
following cases :-
• Before the following functions :-
sin, cos, tan, sin
–1
, cos
–1
, tan
–1
, sinh, cosh, tanh, sinh
–1
,
cosh
–1
, tanh
–1
, log, ln, 10
x
, e
x
, ,
3
, Pol(x,y), Rec(r, )
example: 2sin30, 10log1.2, 23, 2Pol(5, 12), etc.
• Before fixed numbers, variales and memories :-
example: 2π, 2AB, 3Ans, etc.
• Before parentheses :-
example: 3(56), (A1)(B1), etc.
Continuous Calculation Function
Even if calculations are concluded with the [=] key, the
result obtained can be used for further calculations. In
this case, calculations are performed with 10 digits for the
mantissa which is displayed.
Example: To calculate 3.14 continuing after 34=12
[ON/AC] [3] [] [4] [=]
(continuing) [] [3] [•] [1] [4]
[=]
Example: To calculate 133 =
[AC] [1] [] [3] [] [3] [=]
[1] [] [3] [=]
(continuing) [] [3] [=]
This function can be used with Type A functions ( x
2
, x
–1
,
x!), , , x
y,
x
and º' ".
Example: Squaring the result of 786=13
[ON/AC] [7] [8] [] [6] [=]
(continuing) [x
2
]
[=]
Replay Function
This function stores formulas that have been executed.
After execution is complete, pressing either the [3] or
[4] key will display the formula executed.
Pressing [4] will display the formula from the beginning,
with the cursor located under the first character.
Pressing [3] will display the formula from the end, with
the cursor located at the space following the last
character. After this, using the [4] and [3] to move the
cursor, the formula can be checked and numeric values or
commands can be changed for subsequent execution.
Example:
[ON/AC] [1] [2] [3] []
[4] [5] [6] [=]
[4]
[=]
[3]
hyp M STO RCL SD REG Fix Sci
S A D R G
– 1 –
– 2 –
– 3 –
– 4 – – 8 – – 12 – – 16 –
– 9 – – 13 – – 17 –
– 10 – – 14 – – 18 –
– 11 – – 15 – – 19 –
– 5 –
– 6 –
– 7 –
3E5÷7
42857.14286
D
123
_
0.
D
A=
123.
D
_
0.
D
A=
123.
D
123X456
_
0.
D
B=
56088.
D
_
0.
D
B=
56088.
D
3E5÷7 4 2 8 5 7
0.1428571
D
369xx2_
D
0.
2.36
2
_
D
0.
369x2
D
0.
2.36
2
D
0.
.36
2
D
0.
sin .36
2
D
0.
Display
Example Operation (Lower)
Percentage
26% of $15.00
Ratio
75 is what % of 250?
15 []26 [SHIFT] [%]
75[]250 [SHIFT] [%]
3.9
30.
Sci 0~9?
Display
Example Operation (Lower)
1006 = 16.66666666
specify 5 significant
digits
Cancel specification by
specifying "Norm" again.
100[]6 [=]
[
Mode
][
Mode
][
Mode
][2][5]
[
Mode
][
Mode
][
Mode
][3][1]
16.66666667
1.6667
01
16.66666667
Display
Example Operation (Lower)
123m456 = 56088m
= 56.088km
78g0.96 = 74.88g
= 0.07488kg
123[]456 [=]
[ENG]
78[]0.96 [=]
[SHIFT] [ENG]
56088.
56.088
03
74.88
0.07488
03
AXB_
0.
D
78÷6
13.
D
Ans
2
_
13.
D
Ans
2
169.
D
123x456
56088.
D
123x456
56088.
D
123x456
_
56088.
D
C=
6898824.
D
_
0.
D
C=
6898824.
D
123_
0.
D
123
123.
D
_
0.
D
_
0.
D
M=
123.
D
M=
136.
D
M=
M
M
M
M
M
M
M
M
123.
D
M=
456.
D
_
0.
D
M=
456.
D
M=
123.
D
456
456.
D
_
0.
D
M=
579.
D
123+456
579.
D
789Ans_
579.
D
789Ans
210.
D
3x4
12.
D
Ans÷3.14_
12.
D
Ans÷3.14
3.821656051
D
1÷3x3
1.
D
1÷3
0.333333333
D
Ansx3
1.
D
12
12.
D
123x456
56088.
D
0
1 2 3
EXP
Ans
DEL
ON/AC
=
+
4 5 6
7 8 9
+
÷
STO
RCL
( )
,
;
M+
º
,,,
hyp
sin
cos
tan
tan
1
M–
DT
cos
1
ln
log
a
b
/c
d
/c
3
x
10
x
e
x
ENG
x
y
x
1
x
3
x
2
nCr
Pol(
nPr Rec(
x!
()
SHIFT
OFF
ALPHA
REPLAY
MODE
Rnd Ran#
%
DRG
π
x
A B C
r
X Y
M
Scl
INS
Mcl
xn xn
1
x y
y
yn yn
1
FE
sin
1
DCBA
CL
COMP SD RE G
1 2 3
Deg Rad Gr a
1 2 3
Fix Sci No r m
1 2 3
_
0.
122_
D
0.
122
D
0.
123_
D
0.
cos 60
D
0.
sin 60
D
0.
cos 60
D
0.
COMP SD RE G
1 2 3
Deg Rad Gr a
1 2 3
D Fix
_
0.0000
Norm 1~2?
Fix Sci No r m
1 2 3
COMP SD RE G
1 2 3
Deg Rad Gr a
1 2 3
Fix Sci No r m
1 2 3
Fix 0~9?
Display
Example Operation (Lower)
1006 = 16.66666666
specify 4 decimal places
cancel specification
200714 = 400
rounded to 3 decimal
places
100 [] 6 [=]
[
MODE
][
MODE
][
MODE
][1][4]
[
MODE
][
MODE
][
MODE
]
[3] [1]
200[]7 [] 14[=]
[
MODE
][
MODE
][
MODE
][1][3]
200 [] 7[ =]
The intermediate result is
automatically rounded
to the specified three
decimal places.
16.66666667
16.6667
16.66666667
400.
400.000
28.571
Display
Example Operation (Lower)
The stored 10-digit
result (28.571421857) is
used when you continue
the calculation by simply
pressing [] or any other
arithmetic function key.
Cancel specification by
specifying "Norm" again.
[]
14 [=]
(The final result is
automatically rounded to
the specified three
decimal places.)
[
MODE
][
MODE
][
MODE
][3][1]
Ans
(upper display)
400.000
400.
Fix 0~9?
Display
Example Operation (Lower)
200714 = 400
rounded to 3 decimal
places
round the stored
intermediate result to
the specified three
decimal places
Cancel specification by
specifying "Norm" again.
200[]7 [] 14[=]
[
MODE
][
MODE
][
MODE
][1][3]
200[]7 [=]
The intermediate result is
automatically rounded
to the specified three
decimal places.
[SHIFT] [Rnd]
[]
14 [=]
[
MODE
][
MODE
][
MODE
][3][1]
400.
400.000
28.571
28.571
Ans
(upper display)
399.994
399.994
Display
Example Operation (Lower)
23 + 4.5 –53 =–25.5
56(–12)(–2.5)=268.8
12369753274103=
6.90368061310
12
(4.510
75
)(–2.3
10
–79
) = –1.03510
–3
(2+3)10
2
=500
(110
5
)7=
14285.71429
(110
5
)714285=
0.7142857
please note that internal calculation is calculated
in 12 digits for a mantissa and the result is
displayed and rounded off to 10 digits.
3 + 5 6 = 33
7 8 4 5 = 36
1 2 3 4 5 6
= 6.6
100 (23) 4 = 80
2 3 ( 4 5 ) = 29
( 7 2 ) ( 8 5 ) = 65
10 { 2 7 ( 3 6 )}
= –55
23 [] 4.5 [] 53 [=]
56[][(–)]12[][(–)]2.5[=]
12369[] 7532 []
74103[=]
4.5[EXP]75 [] [(–)]2.3
[EXP] [(–)]79 [=]
[( ] 2 [] 3[ )][]
10[x
2
] [=]
1[EXP]5 [] 7 [=]
1[EXP]5[]7 []
14285 [=]
3 [] 5 [] 6 [=]
7 [] 8 [] 4 [] 5 [=]
1 [] 2 [] 3 [] 4 []
5 [] 6 [=]
100 [][( ] 2 [] 3[ )]
[] 4 [=]
2 [] 3 [] [(] 4 [] 5 [=]
Closed parentheses
occurring immediately
before operation of the
[=] key may be omitted.
[( ] 7 [] 2 [ )][( ] 8 [] 5 [=]
A multiplication sign [
]
occurring immediately
before an open parantheses
can be omitted.
10 [
][( ] 2 [
] 7 [( ] 3 [
]
6 [=]
–25.5
268.8
6.903680613
12
–1.035
–03
500.
14285.71429
0.7142857
33.
36.
6.6
80.
29.
65.
–55.

Summary of content (2 pages)