TRANSDUCERS HUMIDITY Kele is the Top Provider of Transducer Control Devices, Connecting Sensors and Peripheral Devices. UCP-422 | p. 1419 T-1000 | p. 1431 PWA-2A | p. 1437 EP311 | p. 1435 CP-8551 | p. 1433 TRANSDUCERS ARM Series | p.
TRANSDUCERS Products manufactured in the United States Products that are new to the catalog UPC-722 | p. 1417 TRANSDUCERS EPC Series | p. 1471 UMX-8 | p. 1466 kele.com MODEL/SERIES Electronic Transducers EP-311/313 Series — Electronic / Pneumatic Transducer . . . . . . . . . . . . . . . PWA Series — Pulse / Tri-State-to-Analog Transducer . . . . . . . . . . . . . . . . . UAT-1, UAT-2 Series — Universal Analog Transducer . . . . . . . . . . . . . . . . .
NEW! TRANSDUCERS CURRENT / PNEUMATIC TRANSDUCER UCP-242 DESCRIPTION The UCP-242 Current/Pneumatic Transducer provides low cost pneumatic control of valves, dampers, or other pneumatic devices. The UCP-242 comes with snap-track for easy mounting. Quick-disconnect terminals provide easy wiring removal for servicing. Barbed fittings for 1/4" plastic tubing and an in-line filter are provided. OPERATION The UCP-242 accepts a 4-20 mA signal and outputs 3-15 psig.
TRANSDUCERS NEW! CURRENT / PNEUMATIC TRANSDUCER UCP-242 INSTALLATION Installation Mount the UCP-242 inside a NEMA 1 control panel in a clean, dry environment. Barbed fittings are provided for terminating 1/4" (0.64 cm) plastic tubing. The UCP-242 must be mounted in an upright position (refer to arrows on unit). For best results, the transducer should be mounted within five degrees of upright position. Wire terminations are marked for 4-20 mA operation.
NEW! TRANSDUCERS ELECTRONIC / PNEUMATIC TRANSDUCER UCP-422 SERIES DESCRIPTION The UCP-422 Series electronic/pneumatic transducer provides low-cost pneumatic control of valves, dampers, or other pneumatic devices. The UCP-422 consists of a totallyenclosed transducer with provisions for optional DIN rail or surface mounting in either of two planes. Externally-mounted pneumatic filters are not required. Quick-disconnect terminals provide easy wiring removal for servicing.
TRANSDUCERS NEW! ELECTRONIC / PNEUMATIC TRANSDUCER UCP-422 SERIES INSTALLATION Installation Mount the UCP-422 inside a NEMA 1 control panel in a clean, dry environment. Barbed fittings are provided for terminating 1/4" (0.64 cm) plastic tubing. The UCP-422 must be mounted in an upright position (refer to arrow on unit). For best results, the transducer should be mounted within five degrees of the upright position.
NEW! TRANSDUCERS UCP-422 SERIES M OPTION DESCRIPTION The M Option Manual Output Adjust allows local adjustment of the UCP-422 output. This feature simplifies checkout and troubleshooting and is available in both loop-powered and 24V-powered configurations. The 24V-powered configuration is provided standard when the M Option is ordered with the (F) Feedback, (V) Voltage, (44) Pulse Width, or (44T) Tri-state options for the UCP-422.
TRANSDUCERS UCP-422 SERIES F, V OPTIONS DESCRIPTION F Option The Feedback Loop Control F Option outputs a current sourcing 4-20 mA signal representative of the branch output pressure. The standard range is 4-20 mA to 3-15 psig (20.7103.4 kPa). F Option also allows for custom ranging the output (i.e., 4-20 mA to 8-13 psig). Any range from 3-15 psig (with a minimum 5 psig span) can be field-calibrated. This option requires 24 VAC/DC power.
NEW! TRANSDUCERS UCP-422 UCO-44, UCO-44T OPTIONS DESCRIPTION The UCO-44 and UCO-44T Options are designed to be used with the Kele UCP-422 Series electronic/pneumatic transducer. The UCO-44 Option allows the UCP-422 to be controlled by a pulse-width modulated (PWM) signal. The UCO-44T Option allows the UCP-422 to be controlled by a tri-state input signal. These options are mounted in an expander ring attached to the UCP-422. FEATURES • Selectable PWM time base 0.1-2.65, 5.2, 12.85, 25.6, or 0.59-2.
TRANSDUCERS UCP-422 SERIES UCO-44, UCO-44T OPTIONS WIRING PWM board is located in UCO-44 expander ring housing attached to the UCP-422 enclosure.
NEW! TRANSDUCERS UNIVERSAL ELECTRONIC / PNEUMATIC TRANSDUCERS UCP-722 SERIES DESCRIPTION The UCP-722 Series microcontroller based electropneumatic transducer incorporates high performance poppet valve technology and low power coils with digital control to provide unmatched accuracy and proven reliability. In addition to providing reliable, stable operation, the poppet valves used in the UCP-722 consume no air. The UCP-722 features jumper-selectable pressure ranges and an LCD display.
TRANSDUCERS NEW! UNIVERSAL ELECTRONIC / PNEUMATIC TRANSDUCERS UCP-722 SERIES WIRING MANUAL ADJUST INPUT VOLTAGE MODE MODE FROM CONTROL SYSTEM GND/COMMON INPUT SIGNAL POWER ALARM MODE PRESSURE RANGE MODE (option) PRESSURE LOSS ALARM (OPTIONAL) ON OFF Auto Manual 3-15 psi 0-20 psi 0-10V Current Voltage 0-5V POWER GND/COM INPUT SIGNAL TO DIGITAL INPUT – OPTIONAL PRESSURE LOSS ALARM INSTALLATION JUMPER CONFIGURATION QUICK INSTALL INPUT Select CURRENT (4-20 mA) or VOLTAGE (0-5V or 0-10V)
NEW! TRANSDUCERS KELE UNIVERSAL ELECTRONIC / PNEUMATIC TRANSDUCERS UCP-822A SERIES DESCRIPTION The Kele UCP-822A microcontroller based electronic/ pneumatic transducer incorporates high performance poppet valve technology and low-power coils with digital control to provide unmatched accuracy and proven reliability. In addition to providing reliable, stable operation, the poppet valves used in the UCP-822A consume no air. The UCP822A features programmable pressure ranges and an LCD display.
TRANSDUCERS NEW! KELE UNIVERSAL ELECTRONIC / PNEUMATIC TRANSDUCERS UCP-822A SERIES CONFIGURATION INPUT VOLTAGE ALARM SETTING P-LOSS MAN OUTPUT INPUT 0-10V 0-5V TRI-PULL-UP Tristate Timing Network FS Point Zero RUN ALARM OUTPUT 4-20 mA / 0-10V Auto CH1/PWM 24V CH2 OPERATION 4-20 mA 0-10V MODE Subtract Pressure Add Pressure INPUT GND ON OFF Manual 4-20 mA Voltage Tristate PWM Network Control TRISTATE WIRING ALARM 4-20mA 0-10V GND INPUT +24V CH2 CH1/PWM Current/Voltage Control, Current
NEW! TRANSDUCERS DIN RAIL ADAPTER BRACKET DIN-L1 DESCRIPTION The Kele DIN-L1 is designed to allow the vertical mounting of track-mounted components in an assembled panel. Flexibility is provided in mounting transducers and power supplies. The bracket comes with a DIN rail mounting adapter and (2) #8-32 machine screws for easily mounting Snap-Track. Holes are provided to line up with the slots in Snap-Track.
TRANSDUCERS NEW! ELECTRONIC / PNEUMATIC TRANSDUCER IP300 DESCRIPTION The KMC Controls IP300 Electronic / Pneumatic Transducer converts an analog voltage or current input signal into a linear pneumatic output signal of 3 to 15 psig. The pneumatic output provides accurate positioning of dampers and valve actuators used in HVAC systems. The IP300 features three selectable inputs of 1-5 VDC, 2-10 VDC, or 4-20 mA. The unit can be mounted in any orientation with the 3.25" snap track.
NEW! TRANSDUCERS CURRENT / PNEUMATIC TRANSDUCER T-1000 DESCRIPTION The T-1000 Industrial-grade Current / Pneumatic Transducer reduces a supply pressure to a regulated output pressure that is directly proportional to a 4-20 mA input signal. An integral pneumatic volume booster is included in the design to provide high flow capacity up to 20,736 scim (20 m3/hr).
TRANSDUCERS NEW! CURRENT / PNEUMATIC TRANSDUCER 22/07-16 DESCRIPTION The ABB 22/07-16 current/pneumatic transducer is a compact, high performance instrument providing many of the same characteristics that are found on industrial-grade transducers. This I/P transducer is designed for high air capacity HVAC applications where mounting space is limited and an industrial appearance is important.
NEW! TRANSDUCERS ELECTRONIC / PNEUMATIC TRANSDUCER CP-8500 SERIES DESCRIPTION The Kele CP-8500 Series Electronic / Pneumatic Transducers handle a wide variety of pneumatic valve and damper applications that require a 3-15 psig control signal from an electronic controller output. The CP-8551 is a basic two-wire loop-powered unit with 4-20 mA input. The CP-8552 is a 3-wire unit with a jumper-selectable input for 4-20 mA, 6-9 VDC or 0-10 VDC.
NEW! TRANSDUCERS ELECTRONIC / PNEUMATIC TRANSDUCER CP-8500 SERIES WIRING CP-8551 2-wire 4-20 mA loop powered CP-8551 M B Power Common Signal Common Signal Common CP-8511 Wiring CP-8552 24H Voltage Input Signal M B 1 +IV1 24 Vac 50/60 Hz M 3 to 15 psig (21 to 103 kPa to controlled device (direct acting) 2 COM COM Typical Controller CP-8511 B M B 1 +20 V supply: 50 mA maximum current output to drive other devices. +IN 2 COM 1 2 COM terminal is internally connected to 24G.
NEW! TRANSDUCERS ELECTRONIC / PNEUMATIC TRANSDUCER EP-311/313 SERIES DESCRIPTION The Mamac Model EP-311/313 Series incorporates quiet low wattage poppet valves and a pressure sensor to measure and adjust the branch line pressure proportional to the input. This unit has no air consumption and is immune to supply line pressure fluctuations. The Model EP-313 incorporates a manual override switch and, in the manual mode, the pressure can be increased or decreased with two push button switches.
TRANSDUCERS NEW! ELECTRONIC / PNEUMATIC TRANSDUCER EP-311/313 SERIES WIRING Wiring Diagram for 24 VAC Supply Configuration Wiring Diagram for 24 VDC Supply Configuration TRANSDUCERS ORDERING INFORMATION MODEL EP311020 EP311315 EP313020 EP313315 DESCRIPTION Electropneumatic transducer without manual override, 0-20 psig Electropneumatic transducer without manual override, 3-15 psig Electropneumatic transducer with manual override, 0-20 psig Electropneumatic transducer with manual override, 3-15 psig T
NEW! TRANSDUCERS PULSE / TRI-STATE-TO-ANALOG TRANSDUCERS PWA SERIES DESCRIPTION The Kele PWA-1A Pulse-to-analog Transducer converts a DIP switch selectable pulse-width modulation (PWM) input to 0-18V and 0-20 mA outputs (factory set for 1-5V and 4-20 mA). The PWA-1A is furnished in a unique slim-line design housing, which saves panel space, and can be ordered with an optional DIN rail mounting adapter. The PWA-2A is a snap-track mounted version of the PWA-1A.
TRANSDUCERS NEW! PULSE / TRI-STATE-TO-ANALOG TRANSDUCERS PWA SERIES PWA-1A / PWA-2A PWM AND MULTIPLEXED PWM-TO-ANALOG CONTROL MANUAL OUTPUT CONTROL JUMPER SETTINGS The 24V power supply must be connected and the override jumper moved to the MAN OVR position covering the center and inner jumper pins. The manual adjustment potentiometer can then be used to vary the output.
NEW! TRANSDUCERS PULSE / TRI-STATE-TO-ANALOG TRANSDUCERS PWA SERIES PWA-1T / PWA-2T TRI-STATE-TO-ANALOG CONTROL MANUAL OUTPUT CONTROL JUMPER SETTINGS MAN OVR Automatic Control The 24V power supply must be connected and the override jumper moved to the "MAN OVR" position covering the center and inner jumper pins. The manual adjustment potentiometer can then be used to vary the output.
TRANSDUCERS NEW! PULSE / TRI-STATE-TO-ANALOG TRANSDUCERS PWA SERIES CALIBRATION Tools required: a multimeter and a signal generator. The PWA-1A, PWA-2A, PWA-1T, and PWA-2T outputs are factory set at 4-20 mA and 1-5V. To change the calibration, see the instructions below. After calibration, alternate between minimum and maximum input pulses and fine tune the mA and voltage potentiometers for desired mA or volt outputs (typically just one more pass is necessary).
NEW! TRANSDUCERS UNIVERSAL ANALOG TRANSDUCERS UAT-1, UAT-2 SERIES DESCRIPTION The Kele UAT-1 and UAT-2 Series Universal Analog Transducers are used for analog signal conversion or signal scaling. They will accept a DC voltage, current, or resistive input signal and output a non-isolated voltage or current output. These transducers can be direct or reverse acting and are easily field calibrated to meet a wide variety of applications.
TRANSDUCERS NEW! UNIVERSAL ANALOG TRANSDUCERS UAT-1, UAT-2 SERIES WIRING INPUT JUMPERS HI LO SPN ZERO 1 HI LO Z2 REF ZERO 2 D R ACT 0-18 VDC or 0-20 mA Output Jumper-Selectable, Adjustable INPUT SIGNAL RANGE NRM NRM Z1 1.2 5 10 INPUT SPAN MA V X1 ÷ 10 MA 10V 20V 24 VAC/VDC Power Supply OUT MA V Power LED SIG OUT 24V PWR COM 10V ÷ 10 20V 0-10.9V, 550 mV min span x1 10V 0-20V, 1V min span x1 20V 0-4 mA, 0.22 mA min span ÷ 10 mA 0-40 mA, 2.
NEW! TRANSDUCERS VOLTAGE & CURRENT CONVERTER / RESCALER VTI SERIES DESCRIPTION The Kele VTI Series Voltage and Current Converter / Rescaler will convert voltage signals in the range of 1-19V or current signals in the range of 1.33-76 mA into a 4-20 mA non-isolated signal. This current source signal can be direct or reverse acting and can be used to drive grounded 4-20 mA loads utilizing a single power supply. The VTI also accepts an input from a resistive potentiometer.
TRANSDUCERS NEW! VOLTAGE & CURRENT CONVERTER / RESCALER VTI SERIES WIRING 24 VDC Power Supply 24 VDC Power Supply VTI with XR1 VTI (blue) Voltage or Current Signal (white) (black) (purple) (no connection) (yellow) Locate VTI close to potentiometer to minimize noise pickup. Increase V SIG IN + 24V PWR (blue) (white) COM UCM-SPA or Potentiometer Sensor - any end-to-end value from 100Ω to 10 kΩ. Specify pot range when ordering.
NEW! TRANSDUCERS ISOLATED DC TO DC TRANSMITTER DT13E SERIES DESCRIPTION The DT13E is a signal isolator that accepts a current or voltage input and provides a linearly transferred current or voltage output. The input and output are electrically isolated, making the DT13E useful for ground-loop elimination, common-mode signal rejection and noise pickup reduction. The DT13E is designed to function effectively in electrically noisy environments.
TRANSDUCERS ISOLATED DC TO DC TRANSMITTER DT13E SERIES SETUP / CALIBRATION Table 1 shows the input and output configurations available with the DT13E. Determine the signal requirements for the application, and set the input and output jumpers according to the table. The input jumpers are located on the DT13E near the SIG IN terminals. The output jumpers are located near the SIG OUT terminals.
NEW! TRANSDUCERS UNIVERSAL MATH MODULE UMM-1, UMM-2 SERIES DESCRIPTION The UMM Series universal math module is a unique multifunction micro-computer based interface that can be utilized to solve a variety of signal selection and manipulation applications. The UMM-1 is furnished in a unique slim-line design housing, which saves panel space, and can be ordered with an optional DIN rail-mounting adapter. The UMM-2 is a snap-track mounted version with operation identical to the UMM-1.
TRANSDUCERS UNIVERSAL MATH MODULE UMM-1, UMM-2 SERIES USER-SELECTABLE OPERATING MODES High and Low Signal Selection The UMM configured for this mode will accept two, three, or four analog input signals and output the signal that is either the highest or lowest of the input signals. To increase the number of input signals, UMMs may be cascaded by wiring the output of one UMM to the input of another UMM. Two UMMs wired in this fashion would allow up to seven input signals.
NEW! TRANSDUCERS UNIVERSAL RESISTANCE TRANSDUCER RES-1E SERIES DESCRIPTION The RES-1E Series universal resistance transducer provides a precision resistance output for DDC control of electric actuators or other electronic devices that operate from a variable resistive circuit. Various selectable analog and pulse-width modulated (PWM) inputs are available, and the transducer may be powered from 24 VAC or 24 VDC. The RES-1E is furnished with snap-track for easy mounting.
TRANSDUCERS NEW! UNIVERSAL RESISTANCE TRANSDUCER RES-1E SERIES CURRENT OR VOLTAGE ANALOG CONTROL Option “PLMEM” = power loss memory, option “SLH” = signal loss hold INPUT TYPE Analog Analog Analog Analog Analog Analog Analog Analog Analog Analog Analog Analog Analog Analog Analog Analog SIGNAL RANGE 0-5V 0-10V 0-15V 0-20 mA 1-5V 2-10V 3-15V 4-20 mA 1-5V 2-10V 3-15V 4-20 mA 1-5V 2-10V 3-15V 4-20 mA OPTIONS * * * * No PLMEM, no SLH No PLMEM, no SLH No PLMEM, no SLH No PLMEM, no SLH No PLMEM, with SLH No
NEW! TRANSDUCERS UNIVERSAL RESISTANCE TRANSDUCER RES-1E SERIES PWM CONTROL Option “PLMEM” = power loss memory INPUT TYPE PWM PWM PWM PWM PWM PWM PWM PWM PWM PWM SIGNAL RANGE 0.1-2.65 sec 0.1-2.65 sec 0.1-5.2 sec 0.1-5.2 sec 0.1-12.85 sec 0.1-12.85 sec 0.1-25.6 sec 0.1-25.6 sec 0.59-2.93 sec 0.59-2.
TRANSDUCERS NEW! UNIVERSAL RESISTANCE TRANSDUCER RES-1E SERIES INSTALLATION AND CHECKOUT INSTALLATION Mount the device inside an enclosure near the controlled equipment, avoiding areas of temperature extremes, corrosive vapors, or electromagnetic interference. Use track slots for screw attachment. Note: Protect circuit board from metal filings created during panel construction. Make all connections according to wiring diagram or as shown in the job diagram and in compliance with national and local codes.
NEW! TRANSDUCERS PNEUMATIC TRANSDUCERS EFP, EPW, EPC, PTA AND PTA2 SERIES DESCRIPTION Floating Point to Pneumatic Output Input: Two Digital (relay, triac, transistor) 9-24 VAC/VDC. Output: Jumper selectable 0-10, 0-15, or 0-20 psig air pressure. Rate of Change: 45 sec., 90 sec., 1 min., and 2 min. Manual Override. Power: 24 VDC or 24 VAC @ 180 mA. Size: 4.0"L x 3.5"W x 1.9"H (10.2 x 8.9 x 4.8 cm).
TRANSDUCERS NEW! ELECTRONIC TRANSDUCERS AAR, ARM, ATL, AUD AND 6N1-ISO SERIES DESCRIPTION Analog to Two Relay Outputs. Input ranges and impedance: 0-12 VDC @ 1MΩ, 0-24 VDC @ 20KΩ, 0-20 mA @ 499Ω. Output: Two (2) Form C relays, rated 10 amps @ 120 VAC. Power: 24 VAC or 24 VDC @ 45 mA max. Size: 3.25"L x 2.41"W x 1.00"H (8.26 x 6.12 x 2.54 cm). Input: Analog Output: Two Relays (high and low trip level & adjustable deadband) AAR DESCRIPTION Analog Current or Voltage Rescaling Module.
NEW! TRANSDUCERS ANALOG/PWM/FLOATING POINT TRI-STATE TRANSDUCERS DRN3.1, AIM1, AIM2, AFP AND DRN4 SERIES DESCRIPTION Pulse Width Modulation / Analog / Floating Point to Optically Isolated Resistance Output. Input: 0.1-10, 0-10 sec. duty cycle, 0.023-6, 0.02-5, 0.59-2.93, and 0.1-25.5 sec. Rates of change: available from 30-240 sec., Analog: 0-5, 1-5, 0-10, 2-10, 0-15, 3-15 VDC, 0-20 and 4-20 mA. Output: 12 ranges, 0-135Ω to 0-40 kΩ and Custom. 256 Step Resolution. Power: 24 VDC/VAC @ 250 mA. Size: 4.
TRANSDUCERS NEW! SEQUENCER CONTROL MODULE - SINGLE STAGE UCS-121 SERIES DESCRIPTION The UCS-121 Series is a solid-state device used to control on/off type loads in HVAC and lighting systems from an analog current or voltage signal. The UCS-121 can be used to convert an analog current or voltage signal from a BAS controller or sensor/transmitter into a SPDT digital output. The UCS-121 is provided with a mounting track or in a hub-mount enclosure for easy installation.
NEW! TRANSDUCERS SEQUENCER CONTROL MODULE - SINGLE STAGE UCS-121 SERIES CALIBRATION ORDERING INFORMATION MODEL UCS-121 UCS-121-C UCS-121-H UCS-121-H-C DESCRIPTION Sequencer control module, single stage Sequencer control module, single stage, pre-calibrated Sequencer control module, single stage, hub enclosure Sequencer control module, single stage, hub enclosure, pre-calibrated TR-3 RELATED PRODUCTS Extra long 3-1/4"W x 4'L snap track TRANSDUCERS The UCS-121 can be ordered preset to the application
TRANSDUCERS NEW! SEQUENCER CONTROL MODULE - TWO STAGE UCS-221E DESCRIPTION The UCS-221E is a solid-state device used for multistage control in HVAC systems, sequencing boilers or chillers, or floating/tri-state control of VAV boxes from a single analog signal. The UCS-221E can be used to obtain a digital output from a voltage or current producing sensor. Units may be daisy chained to provide additional stages of control, and a mounting track is supplied for easy installation.
NEW! TRANSDUCERS SEQUENCER CONTROL MODULE - TWO STAGE UCS-221E WIRING Make all connections according to the diagram below or as shown on the job diagrams and in compliance with national and local codes. Make all connections with power removed. Failure to do so could result in circuit board damage. Use shielded #18-gauge cable for connections from the UCS-221E to the controller, shield grounded at the controller. TABLE 1.
TRANSDUCERS NEW! SEQUENCER CONTROL MODULE - FOUR STAGE UCS-421E DESCRIPTION The UCS-421E is a solid-state device used for multistage control in HVAC systems, sequencing boilers or chillers, or floating/tri-state control of VAV boxes from a single analog signal. The UCS-421E can be used to obtain a digital output from a voltage or current producing sensor. Units may be daisy chained to provide additional stages of control, and a mounting track for easy installation.
NEW! TRANSDUCERS SEQUENCER CONTROL MODULE - FOUR STAGE UCS-421E WIRING Make all connections according to the diagram below or as shown on the job diagrams and in compliance with national and local codes. Make all connections with power removed. Failure to do so could result in circuit board damage. Use shielded #18-gauge cable for connections from the UCS-421E to the controller, shield grounded at the controller. TABLE 1.
TRANSDUCERS NEW! KELE SEQUENCER CONTROL MODULE - SIX STAGE UCS-621E DESCRIPTION The UCS-621E is a solid-state device used for multistage control in HVAC systems, sequencing boilers or chillers, or floating/tri-state control of VAV boxes from a single analog signal. The UCS-621E can be used to obtain a digital output from a voltage or current producing sensor. Units may be daisy chained to provide additional stages of control, and a mounting track is supplied for easy installation.
NEW! TRANSDUCERS KELE SEQUENCER CONTROL MODULE - SIX STAGE UCS-621E WIRING Make all connections according to the diagram below or as shown on the job diagrams and in compliance with national and local codes. Make all connections with power removed. Failure to do so could result in circuit board damage. Use shielded #18-gauge cable for connections from the UCS-621E to the controller, shield grounded at the controller. TABLE 1. OTHER DIFFERENTIALS Plug-in Differential Resistors (1/4W, 1%) 18.2 kΩ = 0.
TRANSDUCERS NEW! SEQUENCER CONTROL MODULE - EIGHT STAGE UCS-821E DESCRIPTION The UCS-821E is a solid-state device used for multistage control in HVAC systems, sequencing boilers or chillers, or floating/tri-state control of VAV boxes from a single analog signal. The UCS-821E can be used to obtain a digital output from a voltage or current producing sensor. Units may be daisy chained to provide additional stages of control, and a mounting track is supplied for easy installation.
NEW! TRANSDUCERS SEQUENCER CONTROL MODULE - EIGHT STAGE UCS-821E WIRING Make all connections according to the diagram below or as shown on the job diagrams and in compliance with national and local codes. Make all connections with power removed. Failure to do so could result in circuit board damage. Use shielded #18-gauge cable for connections from the UCS-821E to the controller, shield grounded at the controller. TABLE 1. OTHER DIFFERENTIALS Factory Relay Settings Relay 1: 5.3 mA, 4V Relay 2: 6.
TRANSDUCERS NEW! MULTI-FUNCTION INPUT / OUTPUT EXPANDER UMX-4, UMX-8 DESCRIPTION The UMX-8 is a unique microcomputer-based multifunction interface that expands the input or output capability of building automation controllers. It has eight SPDT output relays that provide on/off control from a jumper-selectable PWM, current or voltage input signal. The sequence of operation can be easily selected by DIP switches. A dual mode allows two UMX-8s to be controlled in sequence from a single input signal.
NEW! TRANSDUCERS MULTI-FUNCTION INPUT / OUTPUT EXPANDER UMX-4, UMX-8 OPERATION Single and Dual UMX Control The UMX can be operated in both a single and dual operating mode. In the single mode, one UMX is controlled from a single current/voltage or PWM signal. In the dual mode, two UMXs are controlled in sequence, providing up to 16 relay outputs from a single current/voltage or PWM input. This dual UMX control is not available with all control sequences.
TRANSDUCERS NEW! MULTI-FUNCTION INPUT / OUTPUT EXPANDER UMX-4, UMX-8 CONTROL SEQUENCES (DIP SWITCHES 5, 6, 7, AND 8) Relay status 0 = Command OFF 1 = Command ON X = No change of state DISCRETE CURRENT AND VOLTAGE COMMANDS mA 5V 10V 15V Note: Each input command may vary to approximately 50% of the change to the next highest or lowest command and still be considered valid. 3.5 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0 TABLE 4.
NEW! TRANSDUCERS MULTI-FUNCTION INPUT / OUTPUT EXPANDER UMX-4, UMX-8 WIRING 5 4 4 V39ZA1 Varistor 5 6 5 6 7 6 Note: 3 3 Any outputs driving an external relay or an inductive load should have a varistor installed at the relay as shown .
TRANSDUCERS MANUAL OVERRIDE BOARDS MOB-4, MOB-8 DESCRIPTION The MOB Series manual override boards are designed to add hand/off/automatic operation to on/off controller outputs. They may also be used as stand-alone override switch banks.
NEW! TRANSDUCERS UNIVERSAL PULSE DIVIDER UPD SERIES DESCRIPTION The UPD Series universal pulse divider accepts pulse signals from devices such as electric meters and flow sensors, rescales these pulses, and provides an isolated pulse output. This allows the receiving devices to monitor higher frequencies than they are able to accept directly. The UPD-2 provides two separate channels and the UPD-4 provides four channels.
TRANSDUCERS TRANSDUCER SELECTION CHART TRANSDUCER SELECTION CHART NEW! TRANSDUCER SELECTION INPUTS TO TRANSDUCERS OUTPUTS FROM TRANSDUCERS PNEUMATIC STANDARD CAPACITY PNEUMATIC HIGH CAPACITY PNEUMATIC INDUSTRIAL CAPACITY RESISTANCE ANALOG (MILLIAMP OR VOLTAGE) VOLTAGE IP-300 UCP-722 UCP-822 EPC UCP-242 UCP-422 CP-8551 CP-8552 CP-8511 IP-300 UCP-722 UCP-822 EPC UCP-422-V CP-8552 CP-8511 EP-311/313 T-1000 22/07-16 RES-1E RES-1E DRN3.1/4 DRN3.