Instructions / Assembly

9
Figure 4 - Completed Ground
GROUNDING KIT INSTALLATION: BIO-LOGIC
®
BIO-1.5 PWP
230V 50/60HZ USING BALLAST NO.10-0504A (CONTINUED)
2. Wrap the copper strap tight around the pipe or metal grounding rod with the sharp edges of the strap facing towards
the item.
3. While keeping the strap tightly around the pipe or metal ground, align one of the holes in the strap with the long
threaded bolt, and tighten using a 7/16" wrench.
(Note: As you continue to tighten the long threaded bolt it begins to press against the end of the grounding strap &
tighten the grip around the pipe or metal ground)
4. Next, insert the bare copper wire into the eye hole in the long threaded bolt, and using a 10mm wrench or
universal pliers tighten the small bolt down onto the copper wire. Ensure that the strap is securely fastened to the pipe
and that the copper wire is in contact with the small bolt.
5. Locate grounding tab
6. Slide grounding connector over grounding tab.
7. Using a Continuity Tester insure that continuity exists between the water purifier chamber and the pipe or metal
ground.
Once completed the ground should appear as shown below.
8. Plug ballast into an approved Ground Fault Circuit Interrupt (GFCI) receptacle. Where a 2-prong or unprotected 3-prong
receptacle is encountered, it must be replaced by a properly grounded Ground Fault Circuit Interrupt (GFCI) receptacle.
Installation must be in accordance with the National Electrical Code and any local codes and ordinances by a qualified
electrician.
9. Once the plumbing hook ups are made, it is a good practice to disinfect the “downstream” plumbing. This is done by
introducing chlorine or other disinfectant solution directly into the purifier chamber, a 100-ppm of chlorine is suggested.
With the disinfectant solution in the purifier chamber, turn the ultraviolet purifier on. Open the “downstream” outlet until
a chlorine odor is noticed. Close the outlet and allow the disinfectant to remain in the plumbing for at least three (3) hours.
Flush the plumbing with ultraviolet purified water; allow the water to run for several minutes before use, this will allow
the ultraviolet lamp to reach its full germicidal output.