KC-3200ZB / BL-6000ZB Wireless Linear Imager Wireless Laser scanner Configuration Guide -1-
Table of Contents Chapter 1 System Information 1.1 About this manual 3 1.2 How to set up the parameter 3 Chapter 2 System Setup 2.1 Terminator 2.2 String Options (Prefix & Suffix) 6 2.3 Setup Insertion 7 Chapter 3 5 BarCode parameters setting 3.1 UPC-A 11 3.2 UPC-E 14 3.3 EAN-13 17 3.4 EAN-8 19 3.5 Code39 21 3.6 Codabar 24 3.7 Code93 28 3.8 Code128 30 3.9 Interleaved2 of 5 33 3.10 Industrial 2of 5 35 3.11 Matrix 2 of 5 37 3.12 China Postage 39 3.
Chapter 1 - System Information 1.1 About this manual This User's Guide provides detailed programming instructions. Barcode scanners are factory programmed for the most common communication setting. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. 1.2 How to set up the parameter -I (1) Scan Start Configuration (2) Scan all necessary labels for parameters that meet your applications. (3) Scan End Configuration to end the programming.
1.2 How to set up the parameter - II Most of time the scanner only requests one read of parameters when changing to new values. You will hear two beeps when you successfully set to the new values. But for some special parameters, multiple reads are needed to complete the configuration. parameters. When use these special In some cases, you might need to read one or more barcodes, such as: Hexadecimal barcodes. For example: prefix, suffix, etc. Numeric barcodes.
Chapter 2 - System setup Start configuration End configuration 2.
2.2 String Options (Prefix & Suffix) This section describes the alterations which can be made to the format of the transmitted data string. A prefix and suffix of maximum 10 direct input may be included in front and at the end of scanned barcode.
2.3 Setup Insertion This section describes how to setup the insertion of output. NOTE : Max. 10 charters can be inserted each time Max. Insertion group is only two.
Example: : To insert character “A” before the third digit(3) Make the decoded data: 12A3456789 How to set up a character you want to insert (1) Scan Start Configuration barcode (2) Scan “G1 Insertion character” (3) Scan “4” and “1” from FULL ASCII Table (4) Scan Confirm configuration barcode (5) Scan End configuration barcode How to set up position you wish to place the character (6) Scan Start Configuration barcode (7) Scan “G1 Character Position” (8) Scan “0” and “3” from FULL ASCII Table
Start configuration End configuration Confirm configuration ITEM OPTION Preamble (Default:00) Ref: Appendix Postamble (Default:00) Ref: Appendix G1 Insertion character (Default:00) Ref: Appendix G2 Insertion character (Default:00) Ref: Appendix G1 Character Position to be inserted (Default:00) Ref: Appendix G2 Character Position to be inserted (Default:00) Ref: Appendix -9-
Start configuration End configuration ITEM OPTION *Disable Bar Code ID Enable * Read 1 Time Accuracy Read 2 Times Positive and negative bar codes Negative bar codes *Positive bar codes Code Type ID Code Type ID UPC-A F Interleaved 25 N UPC-E G Industrial 25 O EAN-13 H Matrix 25 P EAN-8 I China Postal Code Q Code 39 J MSI/Plessey R Codabar K Code 32 S Code 93 L Code 11 T Code 128 M Telepen V - 10 -
Chapter 3 - BarCode parameters setting How to set up a Code ID? (1) Scan Start configuration bar code (2) Go to the ASCII Table and scan label that represent the desired characters to be inserted. (3) Scan Confirm configuration bar code (4) Scan End configuration bar code. Start configuration End configuration Confirm configuration 3.
Start configuration ITEM UPC-A Expand to EAN-13 End configuration OPTION * Disable Enable Check Digit Send Disable * Enable Truncate Leading Zero * Disable Enable Truncate Leading (Default:00) Ref: Appendix (00-0DH) Truncate Ending (Default:00) Ref: Appendix (00-0DH) Insert group selection Ref: Appendix(00—02H) - 12 -
Start configuration ITEM End configuration OPTION * NONE 2 digits Supplement digits 5 digits 2 or 5digits Auto-discriminate Supplement - 13 -
3.
Start configuration ITEM UPC-E Expand to UPC-A End configuration OPTION * Disable Enable Check Digit Send Disable * Enable Truncate Leading (Default:00) Ref: Appendix (00-08H) Truncate Ending (Default:00) Ref: Appendix (00-08H) Insert group selection (Default:00) Ref: Appendix (00-02H) - 15 -
Start configuration ITEM Truncate Leading Zero End configuration OPTION *Disable Enable * None 2 digits Supplement digits 5 digits 2 or 5 digits Auto-discriminate Supplement - 16 -
3.
Start configuration ITEM End configuration OPTION * None 2 digits Supplement digits 5 digits 2 or 5 digits Auto-discriminate Supplement ISBN/ISSN Conversion * Disable Enable Insert group selection (Default : 00 ) Ref: Appendix (00-02H) - 18 -
3.
Start configuration ITEM End configuration OPTION Truncate Ending (Default : 00) Ref: Appendix (00-08H) * None 2 digits Supplement digits 5 digits 2 or 5 digits Auto-discriminate Supplement Insert group selection (Default : 00) Ref: Appendix (00-02H) - 20 -
3.
Start configuration ITEM Append End configuration OPTION * Disable Enable Min. code length (Default: 00) Ref: Appendix (00-32H) Max.
Start configuration ITEM Transmit Start/End Character End configuration OPTION * Disable Enable Truncate Leading (Default: 00) Ref: Appendix (00-32H) Truncate Ending (Default: 00) Ref: Appendix (00-32H) Insert group selection (Default: 00) Ref: Appendix (00-02H) - 23 -
3.
Start configuration ITEM Check-sum verification End configuration OPTION Disable * Enable Check-sum transmission * Disable Enable Append * Disable Enable Truncate Leading (Default:00) Ref: Appendix (00-7EH) - 25 -
Start configuration ITEM End configuration OPTION Truncate Ending (Default:00) Ref: Appendix (00-7EH) * ABCD/ABCD Start/End type abcd/abcd abcd/tn*e Start/End transmission * Disable Enable Min.
Start configuration ITEM End configuration OPTION Max.
3.
Start configuration ITEM Check-sum transmission End configuration OPTION * Disable Enable Min. code length (Default: 00) Ref: Appendix (0-50H) Max.
3.
Start configuration ITEM Check-sum transmission End configuration OPTION * Disable Enable FNC2 Append * Disable Enable UCC/EAN128 * Disable Enable FNC1 transmission * Disable Enable - 31 -
Start configuration ITEM End configuration OPTION Truncate Leading (Default: 00) Ref: Appendix (00-7FH) Truncate Ending (Default: 00) Ref: Appendix (00-7FH) Min. code length (Default: 00) Ref: Appendix (00-7FH) Max.
3.
Start configuration ITEM End configuration OPTION Truncate Leading (Default : 00) Ref: Appendix (00-7EH) Truncate Ending (Default : 00) Ref: Appendix (00-7EH) Min. code length (Default : 04) Ref: Appendix (04-7FH) Max.
3.10 Industrial 2 of 5 Start configuration ITEM Read End configuration OPTICON * Disable Enable Code ID setting (Default : O) Ref: Appendix (20-7EH) Min. code length (Default : 00) Ref: Appendix (00-32H) Max.
Start configuration ITEM End configuration OPTION Truncate Leading (Default : 00) Ref: Appendix (00-32H) Truncate Ending (Default : 00) Check-sum verification Ref: Appendix (00-32H) * Disable Enable Check-sum transmission Disable * Enable Insert group selection (Default : 00) Ref: Appendix (00-02H) - 36 -
3.
Start configuration ITEM Check-sum transmission End configuration OPTION Disable * Enable Truncate Leading (Default : 00) Ref: Appendix (00-50H) Truncate Ending (Default : 00) Ref: Appendix (00-50H) Min. code length (Default : 0B) Ref: Appendix (00-50H) Max.
3.
Start configuration ITEM End configuration OPTION Truncate Leading (Default : 00) Ref: Appendix (00-50H) Truncate Ending (Default : 00) Ref: Appendix (00-50H) Min.code length (Default : 00) Ref: Appendix (00-50H) Max.
3.
Start configuration ITEM Check-sum transmission End configuration OPTION Disable * Enable Truncate Leading (Default : 00) Ref: Appendix (00-3CH) Truncate Ending (Default : 00) Ref: Appendix (00-3CH) Min. code length (Default : 00) Ref: Appendix (00-3CH) Max.
3.
Start configuration ITEM End configuration OPTION Truncate Leading (Default : 00) Ref: Appendix (00-0AH) Truncate Ending (Default : 00) Ref: Appendix (00-0AH) Insert group selection (Default : 00) Ref: Appendix (00-02H) - 44 -
3.
Start configuration ITEM Check-sum transmission End configuration OPTION * Disable Enable Truncate Leading (Default : 00) Ref: Appendix (00-50H) Truncate Ending (Default : 00) Ref: Appendix (00-50H) Min. code length (Default : 00) Ref: Appendix (00-50H) Max.
3.
Start configuration ITEM Check-sum transmission End configuration OPTION * Disable Enable Truncate Leading (Default : 00) Ref: Appendix (00-40H) Truncate Ending (Default : 00) Ref: Appendix (00-40H) Min. code length (Default : 00) Ref: Appendix (00-40H) Max.
3.
Appendix A – - 50 -
Dec Hex Char. Dec Hex Char. 0 00 NUL 32 20 SP 1 01 SOH 33 21 ! 2 02 STX 34 22 “ 3 03 ETX 35 23 # 4 04 EOT 36 24 $ 5 05 ENQ 37 25 % 6 06 ACK 38 26 & 7 07 BEL 39 27 ‘ 8 08 BS 40 28 ( 9 09 HT 41 29 ) 10 0A LF 42 2A * 11 0B VT 43 2B + 12 0C FF 44 2C , 13 0D CR 45 2D - 14 0E SO 46 2E .
Dec Hex Char. Dec Hex Char.
Table-Hex HEXADCIMAL Confirm configuration End Configuration - 53 -
- 54 Version: 3.