Instruction book 
CR 
Install the compressor horizontally, in a cool but frost-free and well-ventilated room. Place the compressor as 
level as possible; however, CR can be operated with a maximum inclination of 40% (22.5 degrees) in any 
direction. The air should be clean. 
It is recommended to install an automatic condensate drain (available as an option) on the air receiver to 
ensure continuous condensate removal. 
CR Contractor 
The compressors are equipped with a lifting eye or yoke. When running, the compressor must be installed as 
level as possible; however, it can be operated temporarily in an inclined plane of maximum 25% (or 20 
degrees). Keep the compressor in a frost-free and well-ventilated place. 
3.2  Electrical connections 
Warning 
The electrical connection must be carried out by an electrician and must correspond to the 
local codes. The indications on the motor data plate must correspond to the power supply 
voltage and frequency. The installation must include an isolating switch in the power line 
near the unit and be protected against short-circuits by fuses for each phase. Refer to 
Fuses and wire sizes. 
The power supply and grounding lines must be of suitable size. Refer to Fuses and wire 
sizes in Section 3.3. 
For  Automatic Start/Stop,  connect  the  power  supply  cables  as  shown  in  the  electrical 
diagrams. Check the setting of the overload relay. 