Product Manual
Table Of Contents
2022 2096 26  5 
Instruction book 
Precautions during installation 
1.  The machine must only be lifted using suitable equipment in accordance with the applicable safety 
regulations. Loose or pivoting parts must be securely fastened before lifting. It is strictly forbidden to dwell 
or stay in the risk zone under a lifted load. Lifting acceleration and deceleration must be kept within safe 
limits. Wear a safety helmet when working in the area of overhead or lifting equipment. 
2.  Place the machine where the ambient air is as cool and clean as possible. If necessary, install a suction duct. 
Never obstruct the air inlet. Care must be taken to minimize the entry of moisture at the inlet air. 
3.  Any blanking flanges, plugs, caps and desiccant bags must be removed before connecting the pipes. 
4.  Air hoses must be of correct size and suitable for the working pressure. Never use frayed, damaged or worn 
hoses. Distribution pipes and connections must be of the correct size and suitable for the working pressure. 
5.  The aspirated air must be free of flammable fumes, vapors and particles, e.g. paint solvents, that can lead to 
internal fire or explosion. 
6.  Arrange the air intake so that loose clothing cannot be sucked in. 
7.  Ensure that the discharge pipe from the compressor to the aftercooler or air net is free to expand under heat 
and that it is not in contact with or close to flammable materials. 
8.  No external force may be exerted on the air outlet valve; the connected pipe must be free of strain. 
9.  If remote control is installed, the machine must bear a clear sign stating: DANGER: This machine is 
remotely controlled and may start without warning.  The operator has to make sure that the  machine is 
stopped and that the isolating switch is open and locked before any maintenance or repair. As a further 
safeguard, persons switching on remotely controlled machines shall take adequate precautions to ensure 
that there is no one checking or working on the machine. To this end, a suitable notice shall be affixed to 
the start equipment. 
10. The machines must be installed in such a way that an adequate flow of cooling air is available and that the 
air from the exhaust does not recirculate to the compressor air inlet or cooling air inlet. 
11. The electrical connections must correspond to the applicable codes. The machines must be earthed and 
protected against short circuits by fuses in all phases. A lockable power isolating switch must be installed 
near the compressor. 
12. On machines with automatic start-stop system or if the automatic restart function after voltage failure is 
activated, a sign stating “This machine may start without warning”  must be affixed near the instrument 
panel. 
13. In multiple compressor systems, manual valves must be installed to isolate each compressor. Non-return 
valves (check valves) must not be relied upon for isolating pressure systems. 
14. Never remove or tamper with the safety devices, guards or insulation fitted on the machine. Every pressure 
vessel or auxiliary installed outside the machine to contain air above atmospheric pressure must be 
protected by a pressure-relieving device or devices as required. 
15. Pipework or other parts with a temperature in excess of 176˚F and which may be accidentally touched by 
personnel in normal operation must be guarded or insulated. Other high-temperature pipework must be 
clearly marked. 
16. If the ground is not level or can be subject to variable inclinations, consult the manufacturer. 
Also  consult  following  safety  precautions:  Safety  precautions  during  operation  and 
Safety precautions during maintenance. 
These precautions apply to machinery processing or consuming air or inert gas. 
Processing  of  any  other  gas  requires  additional  safety  precautions  typical  to  the 
application which are not included herein. 
Some precautions are general and cover several machine types and equipment; 
hence some statements may not apply to your machine. 