Brochure

4
B
A
4
For assured performance and maximum maintenance intervals the
specially designed OSC service kits should be used.
In addition to the buoyant oleophilic and activated carbon bags
needed for one year of normal operation, the kit includes inlet
mufflers and diffusion filters
Atlas Copco also offers a full set of spare parts for each machine
in the range, and a series of options for multiple installations and
for operation in extreme climates.
Dedicated kits have been developed for condensate with high
oil content. Specific kits are available for treating efficiently
condensate containing glycol or silicon based oils.
OSC – benets from the best technology
Complete reliability
from total simplicity
1
Condensate enters through the mufflers and depressurizes
in the expansion chamber.
2
The emulsified oil water mixture then enters tower A and
seeps through the white oleophilic filter. The filter absorbs
the oil but not the water.
3
The oleophilic filter floats on the water and absorbs any
remaining oil from the surface.
The additional weight of the oil causes the filter to
gradually sink as it gets more saturated, which ensures
that clean filter material is always in contact with the
surface of the water.
The indicator stick at the top of tower A shows the status
of the filter; as the filter is consumed, the stick sinks.
The filter has to be changed just before it’s fully sub-
merged.
4
Significantly cleaner condensate flows from tower A
to tower B.
5
Tower B contains a bag of activated carbon pellets which
absorb any residual oil from the condensate.
6
Clean condensate exits from tower B with almost no
residual oil content, enabling it to be discarded easily and
safely.
Make life easy
with genuine OSC service kits
Factory options to suit all requirements
The following options are available and can be fitted on site:
4
low temperature environment kit – consisting of tower
heating and insulation
4
multiple inlet manifold for easy connection of
several condensate lines into one unit
4
anti-bacteria kit
4
electronic alarm sensors for condensate overflow and
filter replacement
1
2
3
4
5
6