Brochure

4
4
Dimensions Weight
Connections
(BSP/NPT)
A B C Inlet Outlet
Model mm inch mm inch mm inch kg lbs inch inch
OSC 35 470 18.5 165 6.5 745 29 4 9 1 x
1
/
2
1 x
1
/
2
OSC 95 680 27 255 10 940 37 13 29 2 x
1
/
2
1 x
1
/
2
OSC 145 680 27 255 10 940 37 15 33 2 x
1
/
2
1 x
1
/
2
OSC 355 750 30 546 21.5 1100 43 25 55 2 x
3
/
4
1 x
3
/
4
OSC 600 750 30 546 21.5 1330 41 26 57 2 x
3
/
4
1 x
3
/
4
OSC 825 945 37 650 26 1450 57 28 62 2 x
3
/
4
1 x
3
/
4
OSC 1200 945 37 695 27 1450 57 30 66 2 x
3
/
4
1 x
3
/
4
OSC 2400 945 37 1185 47 1450 57 60 132 2 x
3
/
4
1 x 1
Cold climate
system FAD
Mild climate
system FAD
Hot climate
system FAD
Model l/s cfm l/s cfm l/s cfm
OSC 35 105 223 45 95 20 42
OSC 95 280 594 118 250 50 105
OSC 145 415 880 175 371 75 160
OSC 355 1035 2194 435 922 190 403
OSC 600 1800 3816 760 1611 330 700
OSC 825 2410 5110 1020 2162 440 933
OSC 1200 3450 7315 1455 3085 630 1336
OSC 2400 6895 14620 2910 6170 1260 2671
Cold climate
system FAD
Mild climate
system FAD
Hot climate
system FAD
Model l/s cfm l/s cfm l/s cfm
OSC 35 65 138 35 75 17 36
OSC 95 180 382 95 201 45 95
OSC 145 270 572 145 307 70 148
OSC 355 665 1410 355 753 170 360
OSC 600 1150 2438 605 1283 290 615
OSC 825 1550 3286 825 1749 400 848
OSC 1200 2220 4706 1180 2502 570 1208
OSC 2400 4440 9413 2360 5003 1145 2427
Hours run per day 8 10 12 14 16 18 20 22 24
Correction factor 1.5 1.2 1 0.86 0.75 0.67 0.6 0.55 0.5
OSD 22-90
Installation with:
compressors - air receivers - dryers and filters
Capacity is based on the compressor running at 7 barg / 100 psig
for 12 hours per day, with all condensate from the compressor, the
air receiver, the filters and fridge dryer being piped into the unit.
Installation with:
compressors - air receivers - filters only
Capacity is based on the compressor running at 7 barg / 100 psig
for 12 hours per day, with all condensate from the compressor, the
air receiver and filters being piped into the unit.
Notes
1) All capacities are based on an outlet oil content of 15 mg/l.
2) Climatic conditions used in the table above are defined as follows:
4
Cold conditions: ambient temperature 15 °C
relative humidity 60 %
4
Mild conditions: ambient temperature 25 °C
relative humidity 60 %
4
Hot conditions: ambient temperature 35 °C
relative humidity 70 %
3) For polyglycol based condensates, the capacity of each unit should be halved.
Running hours
Multiply the OSC FAD capacity by the appropriate correction factor to adjust for
different running hours:
Separation performance
For an outlet oil carryover over 10 mg/l instead of 15 mg/l, multiply the unit capacity
by 2/3. 5 mg/l can also be achieved: contact Atlas Copco for precise derating.
Technical data
OSC 35-2400
Maximum
compressor
capacity
Weight
Oil content
in effluent
Oil canister
volume
Model l/s kg lbs mg oil/l l
OSD 22 60 8 18 1
OSD 90 250 9 20 < 10 2
A
B
C