Product Manual

The water from the first tower, still containing a small quantity of oil, gradually flows to a second tower (9),
where two filters are fitted: a small oleophilic filter, which absorbs some more oil from the condensate, and
an
activated carbon filter (7). The activated carbon filter starts to absorb the remaining oil in the condensate.
The condensate gradually flows to a third tower (10), where another activated carbon filter is fitted, which
absorbs almost all of the remaining oil.
The clean condensate is drained to the condensate outlet (1).
The oleophilic filter floats on the water. The more oil the filter absorbs, the deeper it will sink, and service
indicator (2) will move downwards with the filter. The filter must be replaced when the service indicator is
down.
Instruction book
10 AIF999999