Product Manual

Reference Description
4 Condensate outlet
5 Tower 1
6 Tower 3
7 Tower 2
8 Diffuser
9 Condensate outlet (test)
10 Protector
A Housing part 1
B Housing part 2
Procedure
1.
Install the OSC on a level floor, suitable for taking its weight.
Keep in mind to reserve sufficient free space for replacement of the filters (see section Maintenance).
2. On OSC 355 and OSC 600:
If the three towers stand in one line, rotate the third tower to the front.
It is possible to operate the unit with the three towers in line. However, it is recommended to
rotate
the third tower as described above for easy change of the activated carbon filter in the
third tower. When the unit is operated with the towers in line, they have to be rotated in order
to change the filter. Keep in mind that the unit in operation can be heavy. (See the operating
weight in section Dimension drawing).
3. Stop
the compressor and close the air outlet valve. Switch off the voltage. Depressurise the outlet piping
by opening the manual condensate drain.
4. Connect the automatic drain of the compressor condensate trap to the condensate inlet of the OSC.
The connection can be made using one or both condensate inlets. The piping diameter must be at least 6
mm . The flexible must be laid out in such a way that no pockets are formed where condensate can collect.
5. Connect the condensate outlet of the OSC to the sewer.
The outlet piping should have a section, sufficient to allow the condensate to flow without building up
pressure. An inner diameter of 19 mm (3/4 ") or larger is recommended. See section Dimension
drawing for the connection dimensions.
The OSC must be positioned higher than the sewer and the OSC outlet piping must be
installed with a slight downward slope to the sewer.
Instruction book
AIF999999 13