4 Operating instructions
4.1
Putting into operation (commissioning)
The plastic bag of the filters must be removed. Do not remove the net around the filters.
The activated carbon filter in the second tower must be placed on the flow plate.
On OSC 355 and OSC 600,
do not remove the flow plate. On all other models, the flow plate is not removable.
Check that the activated carbon filters do not float. If necessary, hold them submerged
until they remain down.
Procedure
OSC 35 up to OSC 145:
1.
Remove the lid of the first tower. Take out the oleophilic filter.
2. Remove the lid of the second tower and take out the activated carbon filter. Remove the plastic bag and
put the filter back. Check that the top of the filter is just below the condensate outlet. If not, check that the
filter is resting on the flow plate.
3. Pour clean water into the unit until the water comes out of the condensate outlet.
4. Put the oleophilic filter on the water surface in the first tower. Do not push the filter down.
5. Put back the lids.
OSC 355 up to OSC 1200:
1. Remove the lids. Take the oleophilic filter out of the first tower.
2. Remove the plastic bag from the activated carbon filter in the third tower. Put the filter back and check
that the top of the filter is just below the condensate outlet. If not, check that the filter rests on the bottom
of the vessel.
3. Take the small oleophilic filter and the activated carbon filter out of the second tower. Remove their bags.
First put back the activated carbon filter, then the small oleophilic filter. Fit the lid and check that the
service indicator is free to move.
4. Pour clean water into the unit until the water comes out of the condensate outlet.
5. Put the oleophilic filter back on the water surface of the first tower. Do not push the filter down.
6. Refit the lids.
OSC 2400:
The steps in section OSC 355 up to OSC 1200 must be done for the left side and for the right side.
Instruction book
14 AIF999999