7.3 Specific data FD30, FD40 and FD60 1)
FD30 FD40 FD60 FD30HP FD40HP
Volume flow at dryer inlet at nominal conditions 50 Hz l/s 30 40 60 43 57
60 Hz l/s 34 50 62 44 --
Pressure drop through dryer at nominal conditions,
approx. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Hz bar 0.14 0.20 0.19 0.11 0.16
60 Hz bar 0.14 0.11 0.19 0.09 --
Electric power input . . . . . . . . . . . . . . . . . . . . . . 50 Hz kW 0.47 0.54 0.86 0.56 0.65
60 Hz kW 0.70 1.01 1.01 0.80 --
Refrigerant
Tetrafluoroethane CH
2
FCF
3
. . . . . . . . . . . . . . . . R134a R134a R134a R134a R134a
Total charge, approx. . . . . . . . . . . . . . . . . . . . . . 50 Hz kg 0.72 0.74 1.20 0.72 0.74
60 Hz kg 0.74 1.20 1.20 0.74 --
7.4 Specific data FD80, FD100 and FD120 1)
FD80 FD100 FD120
Volume flow at dryer inlet at nominal conditions . . . . . . . . . . 50 Hz l/s 80 100 120
60 Hz l/s 90 108 132
Pressure drop through dryer at nominal conditions, approx.. . 50 Hz bar 0.15 0.20 0.15
60 Hz bar 0.15 0.13 0.15
Electric power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Hz kW 1.10 1.30 1.40
60 Hz kW 1.40 1.60 2.10
Refrigerant
Tetrafluoroethane CH
2
FCF
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . R404a R404a R404a
Total charge, approx. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Hz kg 0.80 1.00 1.10
60 Hz kg 1.00 1.10 1.10
8 CONVERSION LIST OF SI UNITS INTO BRITISH UNITS
1 bar = 14.504 psi
1 g = 0.035 oz
1 kg = 2.205 lb
1 km/h = 0.621 mile/h
1 kW = 1.341 hp (UK and
US)
1 l = 0.264 US gal
1 l = 0.220 Imp gal (UK)
1 l = 0.035 cu ft
1 m = 3.281 ft
1 mm = 0.039 in
1 m
3
/min = 35.315 cfm
1 mbar = 0.401 in wc
1 N = 0.225 lbf
1 Nm = 0.738 lbf.ft
1) At nominal conditions
2) A temperature difference of 1°C = a temperature difference of 1.8°F