In case the filter cannot be depressurized by venting via the drain port, do not continue with
the filter element change and contact your supplier for further assistance.
5. Discard the used filter element.
6. Position the new filter element on top of the bowl and align the filter element fin with the
groove in the top of the hexagonal nut, as can be seen in the figure below.
This is the only correct way the filter element can be installed, fitting the fin of the filter
element in the foreseen space in the inPASS™ valve.
7. Screw the bowl (with the filter element resting on top) completely on the head.
8. Change the filter back to filter mode by rotating the inPASS™ valve according to the
instructions from section inPASS™ instructions.
9. Replace smart service indicator batteries with new high-quality batteries or directly connect
to the external power supply. Refer to section Smart service indicator for detailed
instructions.
10. Reset the smart service indicator to restart tracking of the next service interval. Refer to
section Smart service indicator for detailed instructions.
A small amount of acid-free vaseline may be applied to the threads and O-ring of the bowl
to facilitate the assembly. No lubricant of any sort should be used on the filter element seal
or inPASS™ seals.
Instruction book
26 2920 7199 41