Product Manual

Table Of Contents
5 Technical data
5.1 Reference conditions
Air inlet pressure 7 bar(e) 102 psig
Air inlet temperature 20˚C 68 ˚F
Ambient temperature 20˚C 68 ˚F
Compressed air inlet dewpoint 3˚C 37 ˚F
5.2 Principal data
Maximum compressed air inlet pressure
(for inPASS™ filters size 380–510)
14 bar(e) 203 psig
Maximum compressed air inlet pressure
(for all other filters)
16 bar(e) 232 psig
Maximum compressed air inlet temperature 65˚C 149˚F
Minimum compressed air inlet pressure 1 bar(e) 15 psig
Minimum compressed air inlet temperature 1˚C 34˚F
Minimum ambient temperature 1˚C 34 ˚F
Maximum recommended pressure drop (worst case)
(not for QD+ filters)
0.35 bar(e) 5 psig
Design temperature of the pressure casting 120 ˚C 248 ˚F
Maximum expected pressure drop over filter housing in inPASS™
mode
1 bar(e) 15 psig
5.3 Specific data
DD+/PD+/UD+
DD+ PD+ UD+
Oil aerosol
removal
performance
according to
ISO12500-1:2
007
Inlet oil
aerosol
concentration
mg/m³ 10 10 10
Average wet
pressure drop
mbar 120 130 235
Oil carry-over
(1)
mg/m³ < 0.1 < 0.01 < 0.001
Instruction book
30 2920 7199 41