Product Manual

Oil level sight-glass
Step Action
If more than 3 months have passed between assembly and installation, make sure
to lubricate the compressor before starting up:
Remove the front panel.
Unscrew the fixing bolts on the top and remove the panel.
Unscrew the cover of the air filter (AF) and remove the filter element.
Open valve (7) and drain approximately 0.2 l (0.05 US gal / 0.04 Imp gal) of oil into
a clean receptacle. Carefully pour this oil through the filter housing into the
compressor element.
Fit the air filter and screw on the filter cover.
Refit the top and front panels.
Check the oil level.
Stop the unit and wait for the foam to disappear (normally about 3 minutes). The oil level
should be visible on the sight glass (SG). Never measure the oil level on a unit that has
been stopped for more than 10 minutes. Do not overfill. Always use the same type of oil.
Instruction book
2920 7199 10 57