Product Manual

Dryer manual drain
This procedure should be carried out at the end of the compressor’s service life.
Step Action
1 On Full-Feature units: move switch (3) of the dryer to position 0.
Stop the compressor and close the air outlet valve (2).
2 Switch off the voltage and disconnect the compressor from the mains.
3 Depressurize the compressor by opening plug (3) one turn.
Push condensate manual drain (Dm) for a few seconds to release any condensate from
the dryer.
Open condensate drain valve (4) of the air receiver.
4 Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor from the air net.
5 Drain the oil and condensate circuits.
6 Disconnect the compressor condensate outlet and valve from the condensate net.
Instruction book
2920 7199 10 65