Brochure

Dual pressure set point
Most production processes create fluctuating demands which, in turn, can create energy
waste in low use periods. Using the Elektronikon
®
, you can manually or automatically create
two different system pressure bands to optimize energy use and reduce costs.
Integrated Saver Cycles
Fan Saver Cycle reduces the energy consumption by switching off the fan in light load
applications. Using an ambient sensor to monitor the required dew point suppression, the
Elektronikon
®
starts and stops the dryer, minimizing energy use.
Week timer
An on-board clock enables timers to be set up to support any working scheme – per day, per
week or completely customizable to your specific situation and needs.
The next-generation Elektronikon
®
operating system offers a wide variety of control and monitoring features that allow you to
increase your compressor’s efficiency and reliability. To maximize energy efficiency, the Elektronikon
®
controls the main drive motor
and regulates system pressure within a predefined and narrow pressure band.
A step ahead in monitoring and controls