Product Manual
Converter fault codes
If a problem is detected by the converter, a specific code (Main motor converter alarm) will appear on the
Elektronikon
display, together with a fault code. Below table lists the most important error codes. If another
code appears, please contact Atlas Copco.
Typical display when the compressor is stopped by a shutdown
(1) Shutdown
Navigate to the Stop icon or to the Protections icon and press Enter.
(1) Protections
(1) General
The display shows the problem (Main Motor Converter Alarm) and a fault code (31 in this case).
Instruction book