Product Manual

8.3 Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute) bar 1
Air inlet pressure (absolute) psi 14.5
Air inlet temperature ˚C 20
Air inlet temperature ˚F 68
Relative humidity % 0
Working pressure See section Compressor data.
Limitations
Maximum working pressure See section Compressor data.
Minimum working pressure bar(e) 4
Minimum working pressure psig 58
Maximum air inlet temperature ˚C 46
Maximum air inlet temperature ˚F 115
Minimum ambient temperature ˚C 1
Minimum ambient temperature ˚F 34
8.4 Compressor data
Reference conditions
All data specified below apply under reference conditions, see section Reference
conditions and limitations.
Common compressor data
Unit
Number of compression stages 1
Temperature of the air leaving the outlet valve (approx.), Workplace ˚C 30
Temperature of the air leaving the outlet valve (approx.), Workplace ˚F 86
Temperature of the air leaving the outlet valve (approx.), Workplace Full-Feature ˚C 30
Temperature of the air leaving the outlet valve (approx.), Workplace Full-Feature ˚F 86
Refrigerant type, Workplace Full-Feature R410a
GA 18 VSD+
Normal effective working pressure bar(e) 4 7 9.5 12.5
Instruction book