Product Manual
- Check the oil level, the oil level should reach the bottom of the oil filler neck (FC).
Minimum level should reach the oil sight glass (GI) when the compressor is stopped.
If needed, top up the oil.
Take care that no dirt drops into the oil system.
Refit and tighten the filler plug (FC).
- Provide labels, warning the operator that:
•
The compressor may automatically restart after voltage failure (if activated, consult Atlas Copco).
•
The compressor is automatically controlled and may be restarted automatically.
•
The compressor may be remotely controlled.
- Check the rotation direction of the axial fan motor. If the rotation direction is wrong, open the isolating
switch in the voltage supply line and reverse two incoming electric lines.
- Check the programmed settings. Consult section Programmable settings.
- Open the air outlet valve.
Start and run the compressor for a few minutes. Check that the compressor operates normally.
Instruction book
86 2920 7110 00