Product Manual

Taking out of operation
- Disconnect the compressor from the mains.
- Unscrew the oil filler plug only one turn to permit any pressure in the system to escape.
- Shut off and depressurise the part of the air net which is connected to the outlet valve. Disconnect
the compressor air outlet pipe from the air net.
- Drain the oil.
- Drain the condensate circuit and disconnect the condensate piping from the condensate net.
Instruction book