Product Manual
Each plan has a programmed time interval at which all service actions belonging to that plan are to be carried
out.
When reaching the interval, a message will appear on the screen indicating which service plans are to be
carried out. After servicing, the intervals must be reset, see section Service menu.
Preventive maintenance schedule
Daily and 3-monthly check list
Period Operation
Daily Check oil level. If needed, top up the oil (see section Operations instructions / During
operation)
Check readings on display.
Check that condensate is discharged during operation.
Drain condensate.
monthly Check that condensate is discharged when pressing the test button on top of the electronic
water drain.
3-monthly (1) Check coolers, clean if necessary.
Remove the air filter element and inspect. Replace damaged or heavily contaminated
elements.
Check the filter elements of the electric cabinet. Replace if necessary
Check list for compressors with dryer
Period Operation
Daily Check that condensate is discharged during operation.
Monthly (1) Drain inspection: Check that condensate is discharged when pressing the test button on
top of the electronic water drain(s).
Condenser cleaning:
•
Stop the compressor, close the air outlet valve and switch off the voltage.
•
Remove any dirt on the condenser inlet with a vacuum cleaner.
•
Next,
clean with an air jet in the reverse direction to normal flow. Use low pressure air.
Keep the compressed air nozzle more than 30 cm away from the condenser to avoid
damaging the of condenser fins.
•
Remove dust from inside the dryer, e.g. with a vacuum cleaner.
Do not use water or solvents to clean the condenser.
(1): More frequently when operating in a dusty atmosphere.
Preventive Maintenance schedule programmed in the Elektronikon
Instruction book
2920 7110 00 91