Product Manual

Running hours Operation
4000 (1) Change oil and oil filter. (not for Roto-Xtend Duty Fluid)
Replace the air filter element.
Replace the oil separator element.
Check condition of the air intake hose between air filter and compressor element (where
applicable).
Check pressure and temperature readings.
Check operation of cooling fans of converter.
Check blow-off solenoid valve after stopping and pressing the emergency stop button.
Clean coolers. Check and clean cooling fan assembly.
8000 (2)(3) All the actions for 4000 hrs.
Change oil and oil filter.
Replace the filter elements of the electric cabinet.
Replace the non return valve of the scavenge line and blow out the restriction nozzle.
Replace the minimum pressure valve, and replace the thermostatic valve. Remove
carefully.
Replace the electronic drain valve.
Carry out a LED/display test.
Check for possible air and oil leakages.
Have safety valve tested.
(1): or yearly, whichever comes first
(2): or every 2 years, whichever comes first
(3): For all 8000 hours actions, contact Atlas Copco.
The indicated oil exchange intervals are valid for standard operating conditions (see section Reference
conditions and limtations) and nominal operating pressure (see section Compressor data). Exposure of the
compressor
to external pollutants, operation at high humidity combined with low duty cycles or operation at
higher temperatures may require a shorter oil exchange interval. Contact Atlas Copco if in doubt.
Roto-Inject Fluid
Ambient temperature Element outlet
temperature
Exchange interval * Maximum time interval *
up to 25 °C up to 90 °C 4000 hours 1 year
from 25 °C up to 35 °C from 90 °C up to 100 °C 3000 hours 1 year
more than 35 °C more than 100 °C 2000 hours 1 year
Roto-Xtend Duty Fluid
Ambient temperature Element outlet
temperature
Exchange interval * Maximum time interval *
up to 40 °C up to 110 °C 8000 hours 2 year
more than 40°C more than 110 °C 6000 hours 2 year
Roto-Foodgrade Fluid
Instruction book
92 2920 7110 00