Product Manual

Open the condensate drain valve (Dm) to depressurise the cooler. (see Condensate system) and close
again.
Unscrew
the oil filler plug (FC) just one turn to permit any remaining pressure in the system to escape.
10. Fill the air receiver (AR) with oil until the level reaches the filler neck. (see Operating instructions /
During operation)
Refit and tighten filler plug (FC).
When the oil level is too low, go back to step 7.
6.6 Coolers
General
Keep the coolers clean to maintain their efficiency.
Procedure
Stop the compressor, close the air outlet valve and switch off the voltage.
Cover all parts under the coolers.
Remove the service plate (1) at the fan compartment.
Remove dirt from the coolers with a fibre brush. Brush in the direction of the cooling fins.
Remove dirt from the fan with a fibre brush.
Clean with an air jet in the reverse direction to normal flow.
If it is necessary to wash the coolers with a cleaning agent, consult Atlas Copco.
After maintenance on the fan and on the coolers:
Remove the loose parts that are used as cover.
Mount the service plate (1) at the fan compartment.
Instruction book
2920 7110 00 97