Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Elektronikon Base Controller
- 3.1 ElektronikonTM Base Controller
- 3.2 Control panel
- 3.3 Icons used on the display
- 3.4 Main screen
- 3.5 Main function
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Service warning
- 3.9 Scrolling through all screens
- 3.10 Calling up running hours
- 3.11 Calling up motor starts
- 3.12 Calling up module hours
- 3.13 Calling up loading hours
- 3.14 Calling up load solenoid valve
- 3.15 Calling up/resetting the service timer
- 3.16 Calling up/modifying pressure band selection
- 3.17 Calling up/modifying pressure band settings
- 3.18 Calling up/modifying the unit of temperature
- 3.19 Calling up/modifying the unit of pressure
- 3.20 Calling up/modifying backlight time
- 3.21 Activating automatic restart after voltage failure
- 3.22 Keyboard lock
- 4 Installation
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Instructions for use
- 11 Guidelines for inspection
- 12 Pressure equipment directives
- 13 Declaration of conformity
6.5 PDX/DDX filter change (option)
Oil filler plug
Drain valve, air receiver
Step Action
1 Stop the compressor, close the air outlet valve, switch off the voltage and depressurise
by unscrewing oil filler plug (3) one turn to permit any pressure in the system to escape.
See section Stopping..
On floor-mouned units, depressurise the filter by opening its drain valve.
If the compressor is fitted onto an air receiver, depressurise the air receiver by opening
condensate drain valve (4).
2 Unscrew the filter bowl. A whistling noise will warn you if the bowl is not fully
depressurised. If this occurs, the bowl should be screwed back and the venting should
be repeated.
3 Remove and discard the filter element.
4 Clean the bowl and replace its O-ring.
5 Fit the new filter element.
Instruction book
64 2920 7191 00