This screen shows the number of loading actions (x1 or - if <x1000> lights up - x1000). In the above
example, the number of unload to load actions is 10100.
3.15 Calling up/resetting the service timer
Starting from the Main screen:
Press Enter button (7) for 3 seconds to enter the Main menu.
Select <dAtA> and press Enter button (7) to enter the Data menu.
Scroll Up or Down buttons (4-8) until <d.6> and <hrs> is shown.
Press Enter button (7): the loading time is shown.
This screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1191>. In the example shown, the
compressor has run 1191 hours since the previous service.
To reset the timer, contact your supplier.
3.16
Calling up/modifying pressure band selection
Starting from the Main screen:
Press Enter button (7) for 3 seconds to enter the Main menu.
Select <ProG> and press Enter button (7) to enter the Programming menu.
After <PASS> blinking, confirm <0> with Enter button (7).
Scroll Up or Down buttons (4-8) to <reG.P> for regulation pressure.
Press Enter button (7) to enter the submenu.