Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Elektronikon Base Controller
- 3.1 ElektronikonTM Base Controller
- 3.2 Control panel
- 3.3 Icons used on the display
- 3.4 Main screen
- 3.5 Main function
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Service warning
- 3.9 Scrolling through all screens
- 3.10 Calling up running hours
- 3.11 Calling up motor starts
- 3.12 Calling up module hours
- 3.13 Calling up loading hours
- 3.14 Calling up load solenoid valve
- 3.15 Calling up/resetting the service timer
- 3.16 Calling up/modifying pressure band selection
- 3.17 Calling up/modifying pressure band settings
- 3.18 Calling up/modifying the unit of temperature
- 3.19 Calling up/modifying the unit of pressure
- 3.20 Calling up/modifying backlight time
- 3.21 Activating automatic restart after voltage failure
- 3.22 Keyboard lock
- 4 Installation
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Instructions for use
- 11 Guidelines for inspection
- 12 Pressure equipment directives
- 13 Declaration of conformity
3.19 Calling up/modifying the unit of pressure
The unit of pressure measurement can only be changed when the compressor is stopped.
Starting from the Main screen:
•
Press Enter button (7) for 3 seconds to enter the Main menu.
• Select <ProG> and press Enter button (7) to enter the Programming menu.
• After <PASS> blinking, confirm <0> with Enter button (7).
• Scroll Up or Down buttons (4-8) to <diSp> for display settings.
• Press Enter button (7) to enter the submenu.
• Scroll Up or Down buttons (4-8) to <PrES> and press Enter button (7).
• The actually used unit is shown. Possible settings are <bar>, <psi> and <MPa>.
• Scroll Up or Down buttons (4-8) to set the unit of pressure and press Enter button (7) to confirm. The
unit blinks and is saved.
3.20 Calling up/modifying backlight time
The backlight will be activated after pressing any button and for the interval of time set in the parameter
<bC.LG> (in sec).
Starting from the Main screen:
• Press Enter button (7) for 3 seconds to enter the Main menu.
• Select <ProG> and press Enter button (7) to enter the Programming menu.
• After <PASS> blinking, confirm <0> with Enter button (7).
• Scroll Up or Down buttons (4-8) to <diSp> for display settings.
• Press Enter button (7) to enter the submenu.
• Scroll Up or Down buttons (4-8) to <bC.LG> and press Enter button (7).
• The current backlight setting is shown. It is possible to set a value between 0s and 120s.
• Scroll Up or Down buttons (4-8) to set the time of backlight and press Enter button (7) to confirm.
The unit blinks and is saved.
3.21 Activating automatic restart after voltage failure
Description
This function allows the compressor to restart automatically after voltage failure. The activation can only
be done by your dealer. Please contact him for further details.
After any power failure, before restarting, the compressor will wait for a fixed time. When delay time is
running, the display will show the related countdown value as below:
Example countdown delay time of automatic restart after power failure.
Instruction book
42 2920 7191 00