Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Elektronikon Base Controller
- 3.1 ElektronikonTM Base Controller
- 3.2 Control panel
- 3.3 Icons used on the display
- 3.4 Main screen
- 3.5 Main function
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Service warning
- 3.9 Scrolling through all screens
- 3.10 Calling up running hours
- 3.11 Calling up motor starts
- 3.12 Calling up module hours
- 3.13 Calling up loading hours
- 3.14 Calling up load solenoid valve
- 3.15 Calling up/resetting the service timer
- 3.16 Calling up/modifying pressure band selection
- 3.17 Calling up/modifying pressure band settings
- 3.18 Calling up/modifying the unit of temperature
- 3.19 Calling up/modifying the unit of pressure
- 3.20 Calling up/modifying backlight time
- 3.21 Activating automatic restart after voltage failure
- 3.22 Keyboard lock
- 4 Installation
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Instructions for use
- 11 Guidelines for inspection
- 12 Pressure equipment directives
- 13 Declaration of conformity
Period (1) Running hours
(1)
Operation
“ 4000 (2) Replace the air filter.
“ 4000 (2) Replace the oil separator.
“ 4000 For compressors with PDX filter, replace the filter.
“ 4000 Check and, if needed, replace the belts.
“ -- Have the safety valve tested.
“ “ Have the operation of sensors, electrical interlockings and
components checked.
“ “ Have the temperature shut-down switch tested.
“ -- Inspect the air receiver.
The air receiver must no longer be used and must be replaced if the
wall thickness is less than the minimum value, specified in the
technical documentation of the air receiver.
“ 8000 (3) If Atlas Copco Roto-Xtend Duty Fluid is used, change the oil.
“ 8000 Service the instrument block: Thermostatic and MPV kit.
“ 8000 Check and clean the inlet valve. Use the unloader kit.
“ 8000 Replace the belts.
(1): whichever comes first.
(2): more frequently in a dusty environment
(3): The indicated oil exchange intervals are valid for standard operating conditions (see section Reference
conditions and limitations) and nominal operating pressure (see section Compressor data). Exposure of the
compressor to external pollutants or operation at high humidity combined with low duty cycles may require
a shorter oil exchange interval. Contact Atlas Copco if in doubt.
Important
• Always consult Atlas Copco if a service timer setting has to be changed.
•
For the change interval of oil and oil filter in extreme conditions, consult your Atlas
Copco Customer Centre.
• Any leakage should be attended to immediately. Damaged hoses or flexible joints
must be replaced.
6.2 Drive motor
General
Keep the outside of the electric motor clean for efficient cooling. If necessary, remove dust with a brush
and/or compressed air jet.
Description
The motor bearings are greased for life.
Instruction book
2920 7191 00 61