Brochure
18 Atlas Copco G 15-22 / GA 15-26 / GA 11
+
-30 / GA 15-37 VSD
+
Atlas Copco G 15-22 / GA 15-26 / GA 11
+
-30 / GA 15-37 VSD
+
19
Tailored to your needs
Some applications may need or may benet from additional options, more rened
control or air treatment systems. To meet these needs, Atlas Copco has developed
options and easily integrated compatible equipment providing the lowest cost
compressed air.
Technical specications G 15-22
G 15-22 GA 15-26 GA 11
+
-30
GA 15-37
VSD
+
Integrated lter (DD
+
or UD
+
) • • • •
Dryer bypass - • • •
Gear/Direct Driven -
Electronic Water Drains (EWD) on coolers • •
Air receiver drain EWD • • N/A N/A
Motor space heater
+
thermistors - • • -
Phase sequence relay -
Tropical thermostat • • • •
Freeze protection - • • -
Heavy duty air inlet lter - • • •
Fan Saver Cycle - • • •
Compressor inlet pre-lter - • • •
Wooden package • • • •
Rain protection - - • -
Lifting device - - • -
Nema 4 & Nema 4X cubicle - - • -
Central control license 4 (EQ4i) or 6 (EQ6i) machines - • • •
Elektronikon
®
Touch* - •
FoodGrade oil • • • •
Roto Synthetic Xtend oil • • • •
Energy recovery - • • •
Modulating control - - • -
Main power isolator switch - • • •
High ambient temperature versions (55°C/131°F for pack, 50°C/122°F for FF) - - • N/A
Dryer Save Cycle - - • •
Performance certicates • • • •
* Except on GA 30. - : Not available : Standard • : Optional
L
W
H
2
3
4
5
6
7
9
10
11
12
13
14
15
16
17
8
1
A
B
C
Oil
Air/Oil
Compressed air
Compressor type
Max. working pressure
Capacity FAD*
Installed motor
power
Noise level**
Weight***
Work Place
WorkPlace
Full Feature
FM
FM
FF
TM
TM
FF
bar(e) psig bar(e) psig l/s m³/hr cfm kW hp dB(A) kg kg kg kg
50 Hz version
G 15
7.5
7.5 108.8 7.3 105 32.4 116.7 68.7 15 20 67 205 268 270 340
10 10 145.0 9.8 141 29.1 104.8 61.7 15 20 67 205 268 270 340
13
13 188.5 12.8 185 22.8 82.1 48.3 15 20 67 205 268 270 340
G 15L****
7.5
7.5 108.8 7.3 105 42.5 153.0 90.1 15 20 67 313 371 493 537
10 10 145.0 9.8 141 38.5 138.6 81.6 15 20 67 313 371 493 537
13
13 188.5 12.8 185 31.2 112.3 66.1 15 20 67 313 371 493 537
G 18
7.5
7.5 108.8 7.3 105 52.1 187.6 110.4 18 25 69 328 392 508 545
10 10 145.0 9.8 141 45.1 162.4 95.6 18 25 69 328 392 508 545
13
13 188.5 12.8 185 38.5 138.6 81.6 18 25 69 328 392 508 545
G 22
7.5
7.5 108.8 7.3 105 62.0 223.2 131.4 22 30 70 344 408 524 561
10 10 145.0 9.8 141 54.1 194.7 114.5 22 30 70 344 408 524 561
13
13 188.5 12.8 185 46.4 167.1 98.3 22 30 70 344 408 524 561
60 Hz version
G 15
100
7.4 107 7.2 104 33.1 119.3 70.2 15 20 68 205 268 270 340
125 9.1 132 8.9 129 29.6 106.7 62.8 15 20 68 205 268 270 340
150 10.8 157 10.6 154 27.3 98.4 57.9 15 20 68 205 268 270 340
175
12.6 182 12.3 178 23.1 83.3 49.9 15 20 68 205 268 270 340
G 15L****
100
7.4 107 7.2 104 44.0 158.4 93.2 15 20 67 313 371 493 537
125 9.1 132 8.9 129 38.8 139.7 82.2 15 20 67 313 371 493 537
150 10.8 157 10.6 154 37.0 133.2 78.4 15 20 67 313 371 493 537
175
12.6 182 12.3 178 32.7 117.7 69.3 15 20 67 313 371 493 537
G 18
100
7.4 107 7.2 104 51.8 186.5 109.8 18 25 69 328 392 508 545
125 9.1 132 8.9 129 46.9 168.8 99.4 18 25 69 328 392 508 545
150 10.8 157 10.6 154 43.3 155.9 91.7 18 25 69 328 392 508 545
175
12.6 182 12.3 178 39.9 143.6 84.5 18 25 69 328 392
508 545
G 22
100
7.4 107 7.2 104 60.5 217.8 128.2 22 30 70 344 408 524 561
125 9.1 132 8.9 129 53.7 193.3 113.8 22 30 70 344 408 524 561
150 10.8 157 10.6 154 48.6 175.0 103.0 22 30 70 344 408 524 561
175
12.6 182 12.3 178 46.0 165.6 97.5 22 30 70 344 408 524 561
* Unit performance measured according to ISO 1217 ed. 4 2009, annex C, latest edition.
** Mean noise level measured at a distance of 1 m according to ISO 2151: 2004 using ISO 9614/2 (sound intensity method); tolerance 3 dB(A).
*** FM: Floor-mounted, FM FF: Floor-mounted Full Feature, TM: Tank-mounted, TM FF: Tank-mounted Full Feature.
**** L = larger drivetrain. This model is part of a dierent series with dierent specications and additional benets: more energy savings, higher FAD, and a lower noise level.
Reference conditions:
• Absolute inlet pressure 1 bar (14.5 psi).
• Intake air temperature 20°C/68°F.
FAD is measured at the following
eective working pressures:
7 bar(e), 9.5 bar(e), 12.5 bar(e)
Maximum working pressure:
13 bar(e) (188 psig)
1
Inlet air lter
2
Inlet valve
3
Compression element
4
Temperature probe
5
Air suction solenoid valve
6
Minimum pressure valve
7
Oil separator element
8
Oil reservoir
9
Oil cooler
10
Aftercooler
11
Evaporator
12
Water separator
13
Capillary tube
14
Condenser
15
Electronic automatic drain
16
Refrigerant compressor
17
Air receiver
A
Full Feature
B
High eciency air lter
C
Electronic receiver drain
FM
Standard
L: 1130 mm, 44.5”
W: 833 mm, 32.8”
H: 1220 mm, 48.0”
FM
Full Feature
L: 1280 mm, 50.4”
W: 833 mm, 32.8”
H: 1220 mm, 48.0”
TM
L: 1921 mm, 75.6”
W: 833 mm, 32.8”
H: 1832 mm, 72.1”
Intake air
Air/oil mixture
Oil
Wet air
Dry air
Water
Refrigerant gas
Refrigerant liquid