Brochure

TECHNICAL SPECIFICATIONS
TYPE
Max. working pressure Capacity FAD* Installed motor power
Noise
level**
Weight
bar(e) psig l/s m
3
/min cfm kW hp dB(A) kg lbs
SF 1-6/2
+
-6
+
(50/60 Hz)
SF 1
8 116 2.9 0.17 6.1 1. 5 2 53 120 265
10 145 1. 9 0.11 4.0 1. 5 2 53 120 265
SF 2 / SF 2
+
8 116 4.2 0.25 8.9 2.2 3 55 125 276
10 145 3.4 0.20 7. 2 2.2 3 55 125 276
SF 4 / SF 4
+
8 116 6.7 0.40 14.2 3.7 5 57 133 293
10 145 5.9 0.35 12.5 3.7 5 57 133 293
SF 6 / SF 6
+
8 116 9.8 0.59 20.8 5.5 7. 5 59 157 346
10 145 7. 6 0.46 16.1 5.5 7. 5 59 157 346
SF 8
+
-22
+
(50/60 Hz)
SF 8
+
8 116 13.4 0.80 28.4 8 10 63 372 820
10 145 11. 4 0.68 24.2 8 10 63 372 820
SF 11
+
8 116 20.3 1.22 43.0 11 15 63 418 921
10 145 15.0 0.90 31.8 11 15 63 418 921
SF 15
+
8 116 27.1 1.63 57.4 15 20 63 580 1278
10 145 23.0 1.38 48.7 15 20 63 580 1278
SF 17
+
8 116 31.1 1.87 65.9 17 22 64 573 1263
10 145 23.7 1.42 50.2 17 22 64 573 1263
SF 22
+
8 116 40.8 2.45 86.5 22 30 65 687 1514
10 145 30.0 1.80 63.6 22 30 65 687 1514
SFD 11
+
-22
+
(50/60 Hz)
SFD 11
+
8 116 9.8 0.59 20.8 11 15 63 450 992
10 145 7. 6 0.46 16.1 11 15 63 450 992
SFD 15
+
8 116 13.4 0.80 28.4 15 20 64 625 1378
10 145 11. 4 0.68 24.2 15 20 64 625 1378
SFD 22
+
8 116 20.3 1.22 43.0 22 30 65 725 1598
10 145 15.0 0.90 31.8 22 30 65 725 1598
SF SKID/TWIN
Skid versions
SF 1
8 116 2.9 0.17 6.1 1. 5 2 65 105 232
10 145 1. 9 0.11 4.0 1. 5 2 65 105 232
SF 2
8 116 4.2 0.25 8.9 2.2 3 67 110 243
10 145 3.4 0.20 7. 2 2.2 3 67 110 243
SF 4
8 116 6.6 0.40 14.0 3.7 5 68 120 265
10 145 5.6 0.34 11. 9 3.7 5 68 120 265
Twin versions - duplex tank mounted
SF 6T
8 116 10.6 0.64 22.5 5.9 8 72 365 805
10 145 9.0 0.54 19.1 5.9 8 72 365 805
SF 8T
8 116 13.2 0.79 81.1 7. 4 10 73 375 827
10 145 11. 2 0.67 68.8 7. 4 10 73 375 827
* Free Air Delivery measured according ISO 1217 ed. 4 2009, Annex C.
** Mean sound pressure level measured according to ISO 2151, with an uncertainty of 3 dB(A).
Weights of the pack & floor-mounted units are shown in the chart.