Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Controller
- 3.1 General
- 3.2 Control panel
- 3.3 Icons used
- 3.4 Main screen
- 3.5 Calling up menus
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Inputs menu
- 3.9 Outputs menu
- 3.10 Counters
- 3.11 Control mode selection
- 3.12 Service menu
- 3.13 Setpoint menu
- 3.14 Event history menu
- 3.15 General settings menu
- 3.16 Info menu
- 3.17 Week timer menu
- 3.18 Test menu
- 3.19 User password menu
- 3.20 Web server
- 3.21 Programmable settings
- 4 Installation guidelines
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Guidelines for inspection
- 11 PED (Pressure Equipment Directive)
- 12 Declaration of conformity
SF 22
+
FF, rear view
1 Compressor module 3 Refrigerant dryer
2 Air cooler 4 Compressed air outlet valve
SFD 22
+
, front view
1 Elektronikon Graphic controller S3 Emergency stop button
2 Electric cabinet
Compressor element operating principle
Each compressor element consists of a fixed scroll shaped housing and a scroll shaped rotor. Air
enters the compressor element through inlet opening (1). Once the air is drawn in, the orbiting
scroll (4) seals the inlet opening and forces the air into a continuously decreasing space. As scroll
(4) keeps orbiting, this process of compression is constantly repeated, resulting in discharging of
oil free compressed air through outlet opening (3).
Instruction book
2920 7140 52 11