Each compressor element is protected by a PT 1000 sensor (6) in the outlet pipe. The sensor is
connected to the electronic regulator.
When the maximum temperature is exceeded, the compressor element is stopped during 2
minutes before it can restart. If this happens 2 times within a time span of 2 hours, the element
will be stopped during 10 minutes. If the compressor element stops a third time within the 2 hours
time span, the element will be shut down and must be reset manually.
3.7 kW compressor module
5.5 kW compressor module
When the compressor is stopped due to overheating, the compressor will not restart
until the failure is acknowledged and the compressor is restarted manually. See also
sections Shutdown warning and Shutdown.