Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Controller
- 3.1 General
- 3.2 Control panel
- 3.3 Icons used
- 3.4 Main screen
- 3.5 Calling up menus
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Inputs menu
- 3.9 Outputs menu
- 3.10 Counters
- 3.11 Control mode selection
- 3.12 Service menu
- 3.13 Setpoint menu
- 3.14 Event history menu
- 3.15 General settings menu
- 3.16 Info menu
- 3.17 Week timer menu
- 3.18 Test menu
- 3.19 User password menu
- 3.20 Web server
- 3.21 Programmable settings
- 4 Installation guidelines
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Guidelines for inspection
- 11 PED (Pressure Equipment Directive)
- 12 Declaration of conformity
3.7 Shutdown
Description
The compressor will shut down in case of:
•
Too high ambient temperature
• Motor overload
• Outlet pressure sensor error
High ambient temperature
If the ambient temperature is above the factory set shutdown temperature (45 °C - 113 °F), the
compressor will be stopped and a stop icon will be shown on the main screen of the controller:
Main screen - shutdown by too high ambient temperature
Text on image
(1) Compressor outlet (3) Shutdown
(2) Stop icon (4) Menu
Motor overload
A motor overload relay protects the motor of each compressor module. The motor is shutdown if
the motor current is too high.
3.8
Inputs menu
Menu icon, Inputs
Function
•
To display the actual value of the measured data (analog inputs) and the status of the digital
inputs (e.g. emergency stop contact, motor overload relay, etc.).
• To select the digital input to be shown on the chart in the main screen.
Instruction book
2920 7140 52 39