Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Controller
- 3.1 General
- 3.2 Control panel
- 3.3 Icons used
- 3.4 Main screen
- 3.5 Calling up menus
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Inputs menu
- 3.9 Outputs menu
- 3.10 Counters
- 3.11 Control mode selection
- 3.12 Service menu
- 3.13 Setpoint menu
- 3.14 Event history menu
- 3.15 General settings menu
- 3.16 Info menu
- 3.17 Week timer menu
- 3.18 Test menu
- 3.19 User password menu
- 3.20 Web server
- 3.21 Programmable settings
- 4 Installation guidelines
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Guidelines for inspection
- 11 PED (Pressure Equipment Directive)
- 12 Declaration of conformity
5 Operating instructions
5.1
Initial start-up
Safety
The operator must apply all relevant Safety precautions.
Initial start-up procedure
1.
Remove the red painted transport brackets (2).
2. Check the settings of the overload relays. See section Electric cable size and fuses.
3.
Connect the compressor electrically. See section Electrical connections.
4. Close the condensate drain valve. See chapter Condensate management in section Flow
diagram.
5. Switch on the voltage. Start and stop the compressor. On 3-phase compressors, check for
correct direction of rotation (direction arrows are provided on the motors). If the rotation
direction is wrong, switch off the voltage and reverse two incoming electric lines.
5.2 Starting
Procedure
1. Open the air outlet valve. See section Introduction for its location.
Instruction book
2920 7140 52 81