Product Manual

Table Of Contents
2. Switch on the voltage.
3.
Close all manual condensate drain valves.
4. Press the start button (1). The compressor starts running and automatic operation LED
lights up.
5. The regulator will automatically stop and start the compressor modules in function of the air
pressure.
6. On compressors with integrated dryer, the nominal pressure dew point will be reached after
a few minutes.
The number of starts is limited to 30 starts per hour. See also section Programmable
settings.
5.3 During operation
Control panel
Procedure
1.
If the automatic operation LED (3) is alight, the regulator is automatically controlling the
compressor modules (starting/stopping).
2. Check the readings on the display (1). In case of a warning or shutdown condition, see
section Problem solving or Event history menu.
3. Check that condensate is discharged automatically from the condensate drain outlet during
operation.
The dew point will deviate from nominal when the nominal conditions are exceeded. If
the dew point remains too high or unstable, consult section Problem solving.
Instruction book
82 2920 7140 52