Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Controller
- 3.1 General
- 3.2 Control panel
- 3.3 Icons used
- 3.4 Main screen
- 3.5 Calling up menus
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Inputs menu
- 3.9 Outputs menu
- 3.10 Counters
- 3.11 Control mode selection
- 3.12 Service menu
- 3.13 Setpoint menu
- 3.14 Event history menu
- 3.15 General settings menu
- 3.16 Info menu
- 3.17 Week timer menu
- 3.18 Test menu
- 3.19 User password menu
- 3.20 Web server
- 3.21 Programmable settings
- 4 Installation guidelines
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Guidelines for inspection
- 11 PED (Pressure Equipment Directive)
- 12 Declaration of conformity
Period
(note 1)
Running
hours (note
1)
Service Plan Operation
Every 3
months
(note 2)
500 -- • Check the pressure drop over the (optional) filters .
•
Inspect the air inlet filters: check for cleanness and
damage. Replace a dirty or damaged filter with a new
one.
• Check the coolers. Clean by air jet if necessary.
Every 6
months
1000 -- • Operate the safety valve.
• Clean the compressor.
• On compressors with integrated dryer:
• Brush or blow off the finned surface of the
condenser.
• Inspect and clean the electronic drain:
• Functioning of the drain can be checked by
pushing the TEST button of the drain.
• Cleaning of the drain filter can be done by
opening the manual drain valve during a few
seconds.
Yearly 2500 -- • Replace the air inlet filters.
• Test the safety valves.
• Have temperature protection and motor overload tested.
• Check tension and condition of the V-belts.
Every 2
years
5000 A • Replace V-belt(s).
• Replace the check valves.
Every 2
years
5000 B 8 bar and 116 psi compressors:
• Clean fan (ref 124 on Flow diagram), fan duct and
element cooling fins (see note 2). See section Cleaning
cooling fins.
• Have orbiting scroll bearing greased (see note 3).
Every 2
years
5000 B 10 bar and 145 psi compressors:
• Replace the element outlet pipe and the plastic insert.
See section Outlet pipe replacement (3.7 kW elements
only).
Note: from S/N API 772 000 onwards, a new type of 3.7
kW compressor element is used. This new element does
no longer have a plastic insert in the outlet pipe and
replacement is no longer required.
• Clean fan (ref 124 on Flow diagram), fan duct and
element cooling fins (see note 2). See section Cleaning
cooling fins.
• Have orbiting scroll bearing and pin crank bearings
greased (see note 3).
• Replace tip seals and dust seal.
• Replace inlet seal.
Instruction book
2920 7140 52 85