Product Manual

Table Of Contents
Period
(note 1)
Running
hours (note
1)
Service Plan Operation
Every 3
months
(note 2)
500 -- Check the pressure drop over the (optional) filters .
Inspect the air inlet filters: check for cleanness and
damage. Replace a dirty or damaged filter with a new
one.
Check the coolers. Clean by air jet if necessary.
Every 6
months
1000 -- Operate the safety valve.
Clean the compressor.
On compressors with integrated dryer:
Brush or blow off the finned surface of the
condenser.
Inspect and clean the electronic drain:
Functioning of the drain can be checked by
pushing the TEST button of the drain.
Cleaning of the drain filter can be done by
opening the manual drain valve during a few
seconds.
Yearly 2500 -- Replace the air inlet filters.
Test the safety valves.
Have temperature protection and motor overload tested.
Check tension and condition of the V-belts.
Every 2
years
5000 A Replace V-belt(s).
Replace the check valves.
Every 2
years
5000 B 8 bar and 116 psi compressors:
Clean fan (ref 124 on Flow diagram), fan duct and
element cooling fins (see note 2). See section Cleaning
cooling fins.
Have orbiting scroll bearing greased (see note 3).
Every 2
years
5000 B 10 bar and 145 psi compressors:
Replace the element outlet pipe and the plastic insert.
See section Outlet pipe replacement (3.7 kW elements
only).
Note: from S/N API 772 000 onwards, a new type of 3.7
kW compressor element is used. This new element does
no longer have a plastic insert in the outlet pipe and
replacement is no longer required.
Clean fan (ref 124 on Flow diagram), fan duct and
element cooling fins (see note 2). See section Cleaning
cooling fins.
Have orbiting scroll bearing and pin crank bearings
greased (see note 3).
Replace tip seals and dust seal.
Replace inlet seal.
Instruction book