Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Controller
- 3.1 General
- 3.2 Control panel
- 3.3 Icons used
- 3.4 Main screen
- 3.5 Calling up menus
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Inputs menu
- 3.9 Outputs menu
- 3.10 Counters
- 3.11 Control mode selection
- 3.12 Service menu
- 3.13 Setpoint menu
- 3.14 Event history menu
- 3.15 General settings menu
- 3.16 Info menu
- 3.17 Week timer menu
- 3.18 Test menu
- 3.19 User password menu
- 3.20 Web server
- 3.21 Programmable settings
- 4 Installation guidelines
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Guidelines for inspection
- 11 PED (Pressure Equipment Directive)
- 12 Declaration of conformity
Replacement procedure
1.
Stop the compressor, depressurize and switch off the voltage.
2. Loosen coupling (3) while immobilizing nipple (2) with a wrench.
3. Remove the outlet pipe together with the nipple.
4.
Fit the elbow and the nipple to the new outlet pipe and tighten. Use only PTFE tape.
5. Fit the plastic insert in place as indicated on the drawing and assemble the outlet pipe with a
maximum torque of 5 Nm (3.7 lbf.ft). Maximum one extra turn (360 °) is allowed for
positioning of the elbow. Do not end turning counterclockwise in order to avoid leaks. Use
only PTFE tape.
Warning: If the outlet pipe is tightened too hard, the thread of the element can get damaged
or the insert can break, resulting in overheating of the compressor element!
6. Fasten coupling (3) while holding nipple (2) with a wrench.
Note
The outlet pipe of the 5.5 kW element and the new 3.7 kW element (see above) does not contain
an insert. Please do not exceed a torque of 15 Nm (hand tightened plus maximum two extra
turns) when assembling.
7.8 Dryer maintenance
(only applicable to compressors with refrigerant dryer)
Safety precautions
The dryer circuit contains refrigerant. When handling refrigerant, all applicable Safety
precautions during maintenance or repair must be observed. Specifically be aware of
following points:
Instruction book