Product Manual

Table Of Contents
8 Adjustments and servicing procedures
8.1
Air filter
Air filter (AF)
Procedure
1.
Stop the compressor, close the air outlet valve and switch off the voltage.
2. Remove the filter cover and the filter element. Discard damaged or clogged elements. Clean the
cover.
3. Fit the new element and reinstall the filter cover.
SF 6
+
has 2 air filters.
8.2 Air cooler
Cleaning
Keep the cooler clean to maintain cooling efficiency. If necessary, remove any dirt with a fibre brush.
Never use a wire brush or metal objects.
Next, clean by air jet in reverse direction of normal flow.
If it is necessary to wash the cooler with a cleansing agent, consult Atlas Copco.
8.3 Drive motor
Instructions
The motor bearings are greased for life and do not require special attention.
Keep the motor free from dust for optimal cooling.
Instruction book
2920 7110 21 125