Product Manual

Table Of Contents
10. Tighten screws (B). Reinstall the inlet baffle.
11.
Check the belt tension after the first 500 running hours.
8.6 Temperature protection
Description
The compressor element is protected by a PT 1000 sensor in the element outlet. The sensor is connected to
the Elektronikon controller.
When the maximum temperature is exceeded, the compressor is stopped. It will restart automatically if the
temperature drops again and if pressure is required. If this happens 4 times within a time span of 1 hour, the
element will be shut down and must be reset manually.
When the compressor is stopped due to repeated overheating, the compressor will not
restart until the failure is acknowledged and the compressor is restarted manually. See
section Shutdown.
Never run the compressor without temperature protection.
8.7 Cleaning the compressor element
Compressor element cooling channels can be hot when the compressor has just
been turned off.
Do not clean the cooling channels with organic solvent since this will damage the
surface treatment.
The purpose of cleaning the cooling channels of a scroll element is to prevent the cooling channels to silt
up and as such reduce the cooling efficiency. A reduced cooling efficiency can lead towards a premature
compressor element failure.
Procedure:
1.
Stop the compressor and switch off the power.
2. Close the air outlet valve and depressurise the compressor.
3. Remove the fan duct:
Unscrew the 3 bolts (1).
Instruction book
128 2920 7110 21