Product Manual

Table Of Contents
Replacement procedure
1.
Stop the compressor, depressurize and switch off the voltage.
2. Loosen coupling (3) while immobilizing nipple (2) with a wrench.
3. Remove the outlet pipe together with the nipple.
4.
Fit the nipple to the new outlet pipe and tighten. Use only PTFE tape.
5. Fit the plastic insert in place as indicated on the drawing and assemble the outlet pipe with a
maximum torque of 5 Nm (3.7 lbf.ft). Do not end turning counterclockwise in order to avoid leaks.
Use only PTFE tape.
Warning: If the outlet pipe is tightened too hard, the thread of the element can get damaged or the
insert can break, resulting in overheating of the compressor element!
6. Fasten coupling (3) while holding nipple (2) with a wrench.
The outlet pipe of the 5.5 kW element does not contain an insert and does not require any maintenance. In
case of disassembly, please apply the same torque and procedure as described above.
Instruction book
130 2920 7110 21