Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Elektronikon controller
- 3.1 General description
- 3.2 Control panel
- 3.3 Icons used on the display
- 3.4 Main screen
- 3.5 Shut-down warning
- 3.6 Shut-down
- 3.7 Service warning
- 3.8 Scrolling through all screens
- 3.9 Calling up element and dew point temperatures
- 3.10 Digital inputs
- 3.11 Calling up running hours
- 3.12 Calling up motor starts
- 3.13 Calling up module hours
- 3.14 Calling up/resetting the service timer
- 3.15 Selection between Local, Remote or LAN control
- 3.16 Calling up/modifying CAN address control
- 3.17 Calling up/modifying IP, Gateway and Subnetmask
- 3.18 Calling up/modifying pressure band settings
- 3.19 Modifying pressure band selection
- 3.20 Calling up/modifying service timer settings
- 3.21 Calling up/modifying unit of temperature
- 3.22 Calling up/modifying unit of pressure
- 3.23 Automatic restart after voltage failure
- 3.24 Activating password protection
- 3.25 Calling up/modifying protection settings
- 3.26 Test screens
- 3.27 Web server
- 3.28 Programmable settings
- 4 Elektronikon Graphic Controller
- 4.1 General
- 4.2 Control panel
- 4.3 Icons used
- 4.4 Main screen
- 4.5 Calling up menus
- 4.6 Shutdown warning
- 4.7 Shutdown
- 4.8 Inputs menu
- 4.9 Outputs menu
- 4.10 Counters
- 4.11 Control mode selection
- 4.12 Service menu
- 4.13 Setpoint menu
- 4.14 Event history menu
- 4.15 General settings menu
- 4.16 Info menu
- 4.17 Week timer menu
- 4.18 Test menu
- 4.19 User password menu
- 4.20 Web server
- 4.21 Programmable settings
- 5 Installation
- 6 Operation
- 7 Preventive maintenance
- 8 Adjustments and servicing procedures
- 9 Problem solving
- 10 Technical data
- 11 Instructions for use
- 12 Guidelines for inspection
- 13 Pressure equipment directives
- 14 Declaration of conformity
The dryer of compressors equipped with a refrigerant dryer has an integrated water separator (201c) and an
electronic water drain (210). The water separator has a manual drain valve (211) and a connection for the
automatic drain. For more details, consult section Refrigerant dryer.
The receiver of receiver mounted compressors has a manual drain valve (122) at the bottom. An electronic
condensate drain is available as option.
On Full Feature compressors equipped with an optional CD desiccant dryer, a PD 20
+
filter (114) equipped
with an automatic drain ensures that no water droplets enter the dryer.
Regulating system and protection
The compressor is controlled by an Elektronikon
®
controller. See the dedicated sections for more details. A
pressure transducer (PIR) and a temperature sensor (TSHH) respectively monitor the air pressure and the
compressor element outlet temperature.
A safety valve (108) protects the compressor element against too high pressure.
2.3
Refrigerant dryer
Operation
The refrigerant dryer removes moisture from the compressed air by cooling it down to near freezing
temperature. The water is removed via an automatic drain.