3 Elektronikon controller
3.1
General description
Control panel
Introduction
The Elektronikon
®
controller has following functions:
Controlling the compressor
Protecting the compressor
Monitoring components subject to service
Automatic restart after voltage failure (see section Activating automatic restart for details)
Controlling the compressor
The regulator maintains the net pressure between programmable limits by automatically starting and
stopping the compressor. A number of programmable settings, e.g. the starting and stopping pressures and
the maximum allowed motor starting frequency are taken into account.
The regulator stops the compressor whenever possible to reduce the power consumption and restarts it
automatically when the net pressure decreases.
Protecting the compressor
Warning / Shutdown
If the compressor element temperature exceeds the factory-set warning level, the compressor will be
stopped for a short time and a warning will appear on the display of the regulator. In case of repetitive
stops due to a too high temperature, a manual reset will be necessary before restarting the compressor.
The compressor will also be stopped when the drive motor is overloaded.
Before remedying, consult the Safety precautions.
Service warning
If the service timer exceeds a programmed value, this will be indicated on the display to warn the operator
to carry out the corresponding service actions.